User manual - ZTA9648O - 49
Enabled
The screen is enabled and accessible from the
device’s main menu.
107 Power-off memory
Defines whether the peak values detected by the rate meter are to be
retained in the device’s internal memory. The values, therefore, are
retained even in the event of a power failure and the next time the device
is switched back on, the stored values are re-presented.
Disabled
(
Default
)
Minimum and maximum peak values of the rate
meter are not stored. When switched on, the peak
values are initialised with value 0.
Maximum peak
Only maximum peak value is retained even in the
event of a power failure. The minimum peak is
initialised with value 0.
Minimum peak
Only minimum peak value is retained even in the
event of a power failure. The maximum peak is
initialised with value 0.
All peaks
Both maximum peak value and minimum peak
value are maintained in the event of a power failure.
11.6
Output Q1..4
Output Q1..Q4 configuration parameters.
111 Source value
(Output Q1)
141 Source value
(Output Q2)
171 Source value
(Output Q3)
201 Source value
(Output Q4)
Defines the data used to manage the output.
None (
Default
)
Output is disabled.
Counter 1
The data used to manage the output logic is the
value of counter 1
Counter 2
The data used to manage the output logic is the
value of counter 2
Rate Meter 1
The data used to manage the output logic is the
value of counter 1