Symptom
Possible Cause
Action
Heating equipment is
running in cool mode.
Heating equipment is not a
heat pump but System Type
(Installer Setup submenu
0170) is set to Heat Pump.
Set System Type (Installer Setup
0170) to match the installed
heating
and/or
cooling
equipment.
Heating
equipment
does not turn off and
heat
temperature
setting is set below
room temperature
Heating equipment is not a
heat pump but System Type
(Installer Setup submenu
0170) is set to Heat Pump.
Set System Type (Installer Setup
submenu 0170) to match the
installed heating and/or cooling
equipment.
Cannot set the system
setting to Heat or
Cool.
System Type is set to Cool
Only or Heat Only or Heat
Only with Fan.
Set System Type (Installer Setup
submenu 0170) to match the
installed equipment.