14
Table 1. Terminal Designation Descriptions.
Terminal Designation
Description
RC (see Note 1)
Power for cooling--connect to secondary side of cooling system 24v
transformer
R (see Note 1)
Power for heating--connect to secondary side of heating system 24v
transformer
C
Common wire from secondary side of 24V transformer
Y
Compressor contactor
G
Fan relay
Y2
Second stage cooling
O/B/W (see Note 2)
Changeover valve for heat pump systems or Heat relay
AUX/W2
Auxiliary heat relay for heat pump systems or Second stage heat relay
E
Emergency heat relay for heat pump systems
L (see note 3)
Equipment alarm monitor for heat pump systems