75
Symptom
Possible Cause
Action
Thermostat is calling
for Heat (Heat on) or
Cool (Cool on) but no
heating or cooling.
Heating or cooling equipment
is not operating.
Check wiring.
Check Installer Setup submenu
0170 and make sure the correct
system type is selected.
Fan does not turn on a
call for heat (electric
furnace).
Fan Control in Heating is set
to Gas or Oil Furnace
(Submenu 0180).
Set Fan Control in Heating to
Electric
Furnace
(Submenu
0180). Which is the factory
default.