To get to the VKB300/200 keyboard Main Menu Press Exit until the screen displays:
1. In the Main Menu, Press the FUN key once. VKB300/200 Keyboard displays:
Press CLR to delete previous data. Input
required VPTZ500 address code XXXX
(
1 1024
)
for control Press Enter for
2. Enter the correct Speed Dome Unit and Press Enter.
Example: Preset Position for Speed Dome 3. VKB300/200 Keyboard displays:
Displays the Speed Dome
Address (1-1024)
3. Now the VKB300/200 Keyboard displays:
13
Preset position (1-128)
Running
speed
(1-64)
Dwell time(1-60)
Press F1 key on the keyboard to move the cursor up and down
4. Press CLR key to delete previous data before programming to a new preset position.
5. Enter desired Preset Position and Press Enter.
6. Press F1 to get to Speed. Using the number keys enter the desired running speed.
7. Press F1 to get to Time. Using the number keys enter the desired dwell time.
For example: Set the running speed of preset position No. 6 as Grade 64 (fastest speed), dwelling time is 5
seconds. Set the running speed of preset position No.2 as Grade 10, dwelling time is 10seconds.
1. Press the FUN key once.
2. Press CLR to clear the data.
3. Input 06 (Note: Setting the Preset Position No. 6) press the Enter Key to Confirm.
4. Press the F1 key to move the cursor to Speed:00
←
5. Input 64, press Enter
6. Press the F1 key to move the cursor to Time:00
←
7. Input 05, press Enter
8. Press F1 to move the cursor back to 1.Position:001
←
9. Press CLR to delete 0006
10. Input 02, press Enter
11. Press the F1 key to move the cursor to Speed:64
←
12. Press CLR to delete 64
13. Input 10, press Enter
Содержание VPTZ500