4. Press Shift + Call for final confirmation.
4.1.2 View Preset Position
Use the VKB300/200 keyboard to view the preset position. (Preset positions are saved in advance).
Input the preset position you would like to view, Data area will display preset position number. Press
Call key, the dome will move to the target place.
For example: View No.5 preset position
1. In the Main Menu, Press CLR to clear the data.
2. Input the preset position you would like to view.
Example: View preset position No. 5
Displays the Preset Position
Number (1-128)
3. Press the CALL key. The dome will move to the Preset Position No. 5
4.2 Dome Pattern Tours
Pattern Tours are a key function of the VPTZ500 dome camera. You can layout the preset position order in
the pattern tours through our advanced program. Using the control keyboard you set the rotation speed for
each preset position and dwell time at each preset position. Only an outer command unit can transfigure the
VPTZ500 dome camera into a pattern tour program route.
4.2.1Preset Position Parameter Setting
VPTZ500 dome camera has the capacity to set up to 128 preset positions through the VKB300/200
keyboard. It can set a running speed at each preset position from 0.4/s to 280/s (1-64grades) and dwell time
from (1-60seconds).
Note: VPTZ500 can rotate at low speeds and at fast speeds. Its speed can be divided into 64 grades. 1 is
the lowest speed and 64 is the fastest speed.