![VorTek SonoPro S34 Series Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/vortek/sonopro-s34-series/sonopro-s34-series_instruction-manual_1050445030.webp)
Series S34 Instruction Manual
Chapter 3 Operation
3-1
M-000-00030
Chapter 3 Operating Instructions
After choosing the installation orientation of the SonoPro
®
Ultrasonic
Flow Meter, you are ready to begin operation. The sections in this
chapter explain the display/keypad commands, meter start-up, and pro-
gramming. To enter parameters and system settings unique to your op-
eration, see the following pages for instructions on using the setup
menus.
Flow Meter Display/Keypad
The flow meter’s digital electronics allow you to set, adjust and moni-
tor system parameters and performance. A full range of commands are
available through the display/keypad. The LCD display gives 2 x 16
characters for flow monitoring and programming. The tactile mem-
brane keypad makes it easy to read the measured parameters or pro-
gram the meter.
Battery LEDs
Each keypad comes standard with two LEDs. The left LED, “EXT.
PWR”, will turn on only when the handheld unit is connected to exter-
nal power (i.e. the charger is plugged in)
. The right LED, “BATT.
CHRG”, will turn on when the bat
tery is charging and turn off when
charging has completed. If the “BATT. CHRG” LED begins
blinking,
there is a problem preventing the battery from recharging. The most
common cause of blinking is a result of the battery becoming too hot or
too cold. The charge rate of the battery is reduced when the internal
temperature of the battery goes above 45 °C (113°F) and below 5°C
(41°F). The battery will stop charging if the internal temperature of the
battery goes above 60°C (140°F) and below -5°C (23°F).
Figure 3-1. Flow Meter Display/Keypad
Содержание SonoPro S34 Series
Страница 34: ...Series S34 Instruction Manual Chapter 3 Operation 3 5 M 000 00030 Output Menu...
Страница 55: ...Series S34 Instruction Manual Chapter 6 Troubleshooting and Repair M 000 00030 6 2 Hidden Diagnostics Menus...
Страница 69: ...Series S34 Instruction Manual Appendix A Specifications A 2 M 000 00030...
Страница 73: ...Series S34 Instruction Manual Appendix C Sound Speed and Pipe Data C 2 M 000 00030 Pipe Chart...
Страница 74: ...Series S34 Instruction Manual Appendix C Sound Speed and Pipe Data C 3 M 000 00030...
Страница 75: ...Series S34 Instruction Manual Appendix C Sound Speed and Pipe Data C 4 M 000 00030...
Страница 76: ...Series S34 Instruction Manual Appendix C Sound Speed and Pipe Data C 5 M 000 00030...
Страница 77: ...Series S34 Instruction Manual Appendix C Sound Speed and Pipe Data C 6 M 000 00030...
Страница 78: ...Series S34 Instruction Manual Appendix C Sound Speed and Pipe Data C 7 M 000 00030...