Series S34 Instruction Manual
Chapter 2 Installation
M-000-00030
2-18
Pulse Output Connections
The pulse output is used for a remote counter of the flow total. When the pre-
set volume or mass (defined in the totalizer settings, see page 3-9) has passed
the meter, the output provides a 50 millisecond square pulse.
The pulse output requires a separate 5 to 36 VDC power supply. The pulse
output optical relay is a normally-open single-pole relay. The relay can con-
duct a current up to 40 mA. It is isolated from the meter electronics and
power supply.
Figure 2-19. Isolated Pulse Output Using External Power Supply
Frequency Output Connections
The frequency output is used for a remote counter of the flow rate. It can be
scaled to output a 1 to 10 kHz signal proportional to mass or volume flow,
temperature, or density.
The frequency output requires a separate 5 to 36 VDC power supply. The
frequency output optical relay is a normally-open single-pole relay. The out-
put can conduct a current up to 40 mA. It is isolated from the meter electron-
ics and power supply.
Freq. Out -
Freq. Out +
Freq. Out voltage = +V
Select resistor so that current
through Freq . Out <= 40 mA
Figure 2-20. Isolated Frequency Output Using External Power Supply
Содержание SonoPro S34 Series
Страница 34: ...Series S34 Instruction Manual Chapter 3 Operation 3 5 M 000 00030 Output Menu...
Страница 55: ...Series S34 Instruction Manual Chapter 6 Troubleshooting and Repair M 000 00030 6 2 Hidden Diagnostics Menus...
Страница 69: ...Series S34 Instruction Manual Appendix A Specifications A 2 M 000 00030...
Страница 73: ...Series S34 Instruction Manual Appendix C Sound Speed and Pipe Data C 2 M 000 00030 Pipe Chart...
Страница 74: ...Series S34 Instruction Manual Appendix C Sound Speed and Pipe Data C 3 M 000 00030...
Страница 75: ...Series S34 Instruction Manual Appendix C Sound Speed and Pipe Data C 4 M 000 00030...
Страница 76: ...Series S34 Instruction Manual Appendix C Sound Speed and Pipe Data C 5 M 000 00030...
Страница 77: ...Series S34 Instruction Manual Appendix C Sound Speed and Pipe Data C 6 M 000 00030...
Страница 78: ...Series S34 Instruction Manual Appendix C Sound Speed and Pipe Data C 7 M 000 00030...
Страница 79: ...Series S34 Instruction Manual Appendix C Sound Speed and Pipe Data C 8 M 000 00030...