If the IP addresses of the AirAura are modified to be compatible with the local
network and that IP address scheme is different from our factory defaults, the IP
address of the Wired side of the wireless module must also be changed.
For instance, if the AirAura’s new hardware IP address and Gateway IP address
are 66.23.77.40 and 66.23.77.1, respectively, then the entry for the Ethernet
Static IP Address should be changed to 66.23.77.40 and the Gateway IP address
changed to 66.23.77.1. Remember, the module’s Ethernet Static IP Address isn’t
really the module’s static IP address; it is the IP address where packets received
on the wireless side of the module will be forwarded.
Please keep in mind that whatever the new Gateway address is, that is the
address a web browser must now be pointed to in order to reach the module’s
configuration interface once it is restarted and the new configuration is in place.
Once changes have been made, scroll down to the bottom of the Network
Settings page and click on the “Commit” button. Then, in order for the new data
to be active the module requires a reboot. You can either reboot the AirAura
itself, or if that is inconvenient, click on the Maintenance tab of the configuration
screen (at the top center of the page) and when that page loads, click on the
“Restart Module” option in the left column of choices.
Note that once the module has been instructed to restart, the browser will lose
contact with the module until it is up and running again. Also, if the Gateway
address has been changed the browser will need to be pointed to that new
address in order to reach the configuration page.
This is important
! If changing the module’s configuration moves it off of the
network address range that the host PC has been using to configure the module,
the host PC’s IP address must
also
be modified in order to put them both on the
same network address range again and re-enable communications.
If difficulties arise with the module configuration, please contact Vorsis Customer
Support at (252) 638-7000 or email them at
.