Group 22
Troubleshooting
159
•
Faulty setting of injection pump
Adjust pump setting.
•
Faulty smoke limiter
– smoke limiter seizing
Overhaul smoke limiter.
– pressure pipe between inlet manifold and smoke
Fit new pressure line
limiter leaking
– faulty diaphragm in smoke limiter
Replace diaphragm in smoke limiter.
– faulty setting
Adjust smoke limiter setting.
•
Stop lever position
Check that the stop lever is in full operating position.
6. Engine runs on
CAUSE
REMEDY
•
One of the semi-automatic fuses in the junction box has
Reset the fuse by pressing the button.
tripped (position 5 in the engine wiring diagram)
•
Poor contact/breaks in connections and electrical cables
Rectify any open-circuits/loose connections. Check for oxi-
dation on the contacts. Clean them and spray with damp-
inhibitor spray. See “Wiring diagrams”.
•
Faulty stop button
Replace stop button.
•
Faulty stop solenoid/fuel shut off valve
Check, replace Stop solenoid/Fuel shut off valve.