Service procedures - fuel system
Group 22
98
Injection pump, setting with
instrument 998 7057
(Injection angle)
Special tools: 999 3590, 998 7057
1
Remove the inspection cover on the camshaft at the back of
the cylinder block.
2
21
Bleed the fuel system and test run the engine. See ”Fuel
system, bleeding”.
Remove the plug in the flywheel cover (16 mm hex socket
key) and fit rotating tool 999 3590 together with a ratchet.
Remove the inspection cover on the flywheel cover.
3
Crank the flywheel in the direction of rotation until 1st
cylinder is on compression, 0° on the flywheel and the
camshaft’s marking hole pointing upwards.
4
Crank the flywheel back against the engine direction of
rotation about 1/4 turn.