INSERTING/REPLACING THE BATTERY

•  Open the battery compartment (2) on the rear. 
•   Insert a battery type AAA/Micro into the battery compartment with the correct polarity (note 

po and negative/-). 

•  Replace the cover on so that it snaps in.
•   Battery replacement is necessary when the display contrast sharply decreases or nothing is 

displayed.

  Due to the low power consumption in standby mode (timer is not running and there is 

no sound output) no on/off switch is required.

 

 If the product is not to be used for a while (e.g. storage for longer than 3  months), 

remove the battery. That way you are preventing that a leaking battery (or a battery) 

may cause damages.

OPERATION

a) Measuring using the puncture probe

Unwind the probe wiring and plug it into the connection socket (3). The long connecting 

wire makes it possible that  both, the puncture probe as well as the thermometer, can be 

positioned optimally outside the oven.
Stick the tip of the puncture probe into the medium to be measured. Wait until the tempera-

ture display has stabilised and no longer (or minimally) changes.
If the measured value is lower than the measurement range, “Lo” is shown; if it is higher, “Hi” 

is shown.

 

 During measurement the puncture probe and the heat-resistant probe wire can 

remain in the oven. The thermometer, however, must be used outside of the oven; 

protect it from temperatures above +40 °C.

 

 Make sure that the probe wire will not get damaged by sharp edges.

   If the probe is used in an induction stove,  it may inherently cause measurement and 

temperature display to malfunction.

b) Setting the temperature limit for the temperature alarm

Set the desired temperature limit using the “UP” (6) or “DOWN” (7) buttons. For a quick 

adjustment, press and hold down the corresponding button for a bit.

c) Switching on/off the temperature alarm

The slide switch “TEMP ALERT ON / OFF” (9) enables or disables the temperature alarm. 
“ON” 

temperature alarm on

“OFF” 

temperature alarm off

If the temperature alarm is switched on, the thermometer will beep when the set temperature 

value is exceeded.

d) Setting/resetting the countdown-timer 

•   The hours of the timer are adjusted with the “HR” button (4); the minutes with the “MIN” 

button (5). 

   For a quick adjustment, press and hold down the corresponding button for a bit.
•   The set timing can be cleared and reset to “0:00:00” by pressing both, the “HR” button (4) 

and “MIN” button (5), simultaneously.

   The timer can only be set/reset when the timer is stopped.

e) Start/Pause/Resume of the Countdown Timer

•   The Timer is started/stopped/resumed with the “START/STOP” (10) button.  
•   When the Countdown-Timer has counted down (at “0:00:00”), an alarm signal sounds. The 

time then resumes on the display. 

   To stop the alarm and reset the timer to the set time, press the “START/STOP” button (10) 

briefly.

f) Toggling between the temperature units °C/°F

Using the slide switch (14) on the rear, you can toggle between the temperature unit °C 

(degrees Celsius) and °F (degrees Fahrenheit).

g) Using the magnetic holder

The thermometer can be attached to an appropriate metal surface through the two built-in 

magnets (11 + 13) located on the rear. 

h) Adjusting the folding display

The folding display allows for custom adjustment of the LCD for better reading. Do not apply 

force, when adjusting; the folding display can only be titled forward/up at an angle of up to 

70°.

CLEANING AND MAINTENANCE

The product does not require any maintenance apart from occasional replacement of the 

battery, and should never be disassembled for any reason.
Clean the product carefully, e.g. with a soft, clean cloth. Do not press too hard on the display; 

this can lead not only to scratches but also to the destruction of the display.
A soft cloth wetted with water and a mild cleaning agent can be used to clean the puncture 

probe. 

   Do not dip the thermometer in or under water. Do not clean the thermometer in a 

dish washer.

 

This will destroy the product and void the warranty!

Never use aggressive cleaning agents and no chemicals at all for cleaning; these can lead 

not only to discolouration, but can also damage the product. 

DISPOSAL

a) General

   Electronic devices are recyclable material and do not belong with household waste.

 

 Please dispose of the device, when it is no longer of use, according to current statu-

tory requirements.

 

 Remove a loaded battery or rechargeable battery and dispose of it separately from 

the product.

b) Batteries and rechargeable batteries

As the end user, you are required by law (Battery Regulation) to return used batteries and 

rechargeable batteries. Do not dispose of used batteries in the household waste!

 

  Single-use/rechargeable batteries containing hazardous substances are labelled 

with this symbol to indicate that disposal in household waste is forbidden. 

 

 You can return single-use/rechargeable batteries free of charge at official collection 

points in your municipality, our stores, or wherever (rechargeable) batteries are 

sold!

You thereby fulfil your statutory obligations and contribute to the protection of the environ-

ment.

TECHNICAL DATA

Power supply ........................................1x battery of type AAA/Micro
Measurement range  ............................0 °C to +200 °C
Resolution .............................................1 °C
Accuracy ...............................................±1 °C
Countdown timer ..................................timer setting 23 hours, 59 minutes
Length of the puncture probe wire ........approx. 110 cm
Length of the puncture probe ...............150 mm
Probe type ............................................type K 
Dimensions ...........................................97 x 68 x 27 mm (L x W x H folded)

..............................................................

80 x 68 x 77 mm (L x W x H opened)

Weight ..................................................110 g (incl. puncture probe, without battery)

Содержание DET-3T

Страница 1: ...Schiebeschalter zum Einstellen der Temperatureinheit C bzw F D BEDIENUNGSANLEITUNG KLAPPTHERMOMETER MIT TIMER DET 3T Best Nr 109982 Bestimmungsgem SSe Verwendung Das Produkt dient zur Temperaturmessun...

Страница 2: ...im Standby Modus Timer l uft nicht und kein Tonsignal wird ausgegeben ist kein Ein Ausschalter erforderlich Wird das Produkt l ngere Zeit nicht benutzt l nger als 3 Monate z B bei Lagerung so sollten...

Страница 3: ...button to stop start the timing 11 Magnet 12 Battery compartment 13 Magnet 14 Sliding switch to toggle temperature units C or F G OPERATING INSTRUCTIONS FOLDING THERMOMETER WITH TIMER DET 3T Item no 1...

Страница 4: ...simultaneously The timer can only be set reset when the timer is stopped e Start Pause Resume of the Countdown Timer The Timer is started stopped resumed with the START STOP 10 button When the Countdo...

Страница 5: ...marrer le minuteur 11 Aimant 12 Compartiment pile 13 Aimant 14 Interrupteur coulissant pour r gler l unit de temp rature C ou F F MODE D EMPLOI THERMOM TRE REPLIABLE AVEC MINUTEUR DET 3 N de commande...

Страница 6: ...s deux touches HR 4 et MIN 5 Le minuteur ne peut tre r gl supprim que lorsque le minuteur est l arr t e D marrer mettre en pause red marrer le minuteur de compte rebours Le minuteur peut tre d marr mi...

Страница 7: ...UITKLAPBARE INSTEEKTHERMOMETER MET TIMER DET 3T Bestelnr 109982 Beoogd gebruik Het product wordt gebruikt voor temperatuurmeting bijvoorbeeld van vloeibare of vaste voedingsmiddelen bij het bakken of...

Страница 8: ...alleen ingesteld of gewist worden als hij gestopt wordt e Countdown timer start pauze hervatten De timer kan met de toets START STOP 10 gestart gepauzeerd en weer hervat worden Als de countdown timer...

Отзывы: