70
You can stop the warning signal by pressing the „BATT TYPE/STOP“ button. You then
return to the previous configuration menu.
Otherwise, the following display may appear (alternatingly):
The „R“ value: indicates the number of cells the charger recognised.
The „S“ value: indicates the number of cells you set in the menu.
If these two numbers do not match, please check the settings on the charger
and the battery itself. It may be that the LiPo battery has been completely
discharged, or a cell may be faulty. In this case, the battery should not be
charged, as there is a risk of fire and explosion!
You can return to the previous configuration menu using the „BATT TYPE/
STOP“ button.
• If the two numbers match, you can start the charging process by briefly pushing the
„START/ENTER“ button.
• Once the charging process has been started, various pieces of information about the
current charging progress are shown on the display - see next image:
Example:
Number of cells Charge Current
Battery Voltage
Current charging duration
Charged capacity in mAh
• Once the charging process has been completed, an audio signal is emitted (if it was not
turned off).
¼
If you wish to terminate the charging process beforehand, push the „BATT TYPE/
STOP“ button.
Li3S 1.2A 12.59V
CHG 022:43 00682
R: 3SER S: 3SER
CONFIRM(ENTER)
R: 3SER S: 3SER
CANCEL(STOP)