86
• With the „INC“ button, you access the next setting (or with the button „DEC“ the previous
setting or return to the main menu with the button „BATT TYPE/STOP“).
In this menu, you can activate/deactivate the temperature monitoring function as well as
set the corresponding temperature at which the safety cut-off kicks in.
¼
An external temperature sensor is required to use this function, which is connected
to the charger (see chapter 8, position 9).
Confirm the selection by pressing the „START/ENTER“ button. „ON“ (or „OFF“) flashes
on the display.
You can activate („ON“) or deactivate („OFF“) the temperature monitoring function with
the buttons „INC“ or „DEC“.
Confirm the setting by pressing the „START/ENTER“ button.
The temperature now flashes in the display (display in °C = „C“ and °F = „F“). With the
buttons „INC“ or „DEC“, you can set the temperature at which a subsequent charge or
discharge process is later terminated.
Save the setting by briefly pushing the „START/ENTER“ button.
• With the „INC“ button, you access the next setting (or with the button „DEC“ the previous
setting or return to the main menu with the button „BATT TYPE/STOP“).
The battery may become quite hot using the cycle program (automatic charge/discharge
cycles in sequence). In order to give the battery enough time to cool off sufficiently, a
break time can be set here.
Briefly push the „START/ENTER“ button. The time then begins to flash. With the buttons
„INC“ or „DEC“, you can select the time (0....60 min). Save the setting with the „START/
ENTER“ button, the time stops flashing.
Waste Time
CHG>DCHG 1min
Temp Cut-Off
ON 80C 176F