44
1 Power switch for putting the device into operation (I=ON/0=OFF)
2 Current display (A) for OUTPUT A
3 Voltage display (V) for OUTPUT A
4 Voltage adjuster (VOLT) for output A
5 Output A status display (CV = constant voltage)
6 Output A status display (OT = overtemperature)
7 Output A status display (CC = constant current)
8 Current adjuster (AMPERE) for output A
9 Status display when overvoltage cut-off active (OVER VOLTAGE) for output A
10 Voltage adjuster (V ADJ.) for output B USB-B1
11 Push switch for voltage range selection of output B USB-B1
12 Flashing status display while while the push button (11) pressed in
13 Current adjuster (A ADJ.) for output B USB-B1
14 Button for displaying the voltage and current setting of output USB-B1
15 Voltage adjuster (VOLT) for output C
16 Output C status display (CV = constant voltage)
17 Output C status display (OT = overtemperature)
18 Output C status display (CC = constant current)
19 Current adjuster (AMPERE) for output C
20 Status display when overvoltage cut-off active (OVER VOLTAGE) for output C
21 Voltage display (V) for OUTPUT C
22 Current display (A) for OUTPUT C
23 USB symbol indicates the display of output B USB-B1
24 Feet on the front, folding
25 “Earth potential” connection socket
26 Level adjuster for overvoltage cut-off (OVP ADJ.) for output C
27 Button to display the set level for overvoltage cut-off for output C
28 Negative of output C connection socket
29 Positive of output C connection socket
30 “C-LIMIT” button for displaying and setting the current limitation of output C
31 Processor-controlled USB output B USB-B2
32 “MODE” switch for selecting the operating mode
33 Adjustable USB output B USB-B1
34 Button to display the set level for overvoltage cut-off for output A
35 Level adjuster for overvoltage cut-off (OVP ADJ.) for output A
36 Negative of output A connection socket