VOLKTEK NSH-580 MANAGED 24-PORT 10/100 + 4 G COMBO L3 SWITCH
Authentication Control:
If “ForceAuthorized” is selected, the selected port is forced
authorized. Thus, traffic from all hosts is allowed to pass. Otherwise, if
“ForceUnauthorized” is selected, the selected port is blocked and no traffic can go
through. If “Auto” is selected, the behavior of the selected port is controlled by 802.1x
protocol. All ports should be set to “Auto” under normal conditions.
Reauthentication:
Once enabled, the switch will try to authenticate the port user
again when the re-authentication time is up.
ReAuthentication Time:
If “Reauthentication” is enabled, this is the time period the
switch uses to re-send authentication request to the port user (see above).
Quiet Period:
If authentication fails, the switch waits for this time period before
sending another authentication request to the port user.
Retransmission Time:
If the port user failed to respond to authentication request
from the switch, the switch waits for this time period before sending another
authentication request to the port user.
Max Reauthent Attempt:
Retry count if the port user fails to respond to
authentication requests from the switch.
Guest VLAN:
Specify a guest VLAN for clients that are not 802.1x-capable.
Click
Submit
to save changes to RAM memory. Click
Refresh
to view effect of changes.
To eventually make all the changes permanent in Flash memory, go to the
Save
Configuration page
(bottom of management menu) and click
Save
.
71