P11K
P15K
P18K
P22K
High/Normal Load
1)
HO
NO
HO
NO
HO
NO
HO
NO
Typical Shaft output hp [kW]
15 [11]
20 [15]
20 [15]
25 [18.5]
25 [18.5]
30 [22.0]
30 [22.0]
40 [30.0]
Enclosure IP20
B3
B3
B4
B4
Enclosure IP21
B1
B1
B2
B2
Enclosure IP55, IP66
B1
B1
B2
B2
Output current
Continuous (3x380–440 V) [A]
24
32
32
37.5
37.5
44
44
61
Intermittent (60 s overload) (3x380–440
V) [A]
38.4
35.2
51.2
41.3
60
48.4
70.4
67.1
Continuous (3x441–500 V) [A]
21
27
27
34
34
40
40
52
Intermittent (60 s overload)
(3x441–500 V) [A]
33.6
29.7
43.2
37.4
54.4
44
64
57.2
Continuous kVA (400 V AC) [kVA]
16.6
22.2
22.2
26
26
30.5
30.5
42.3
Continuous kVA (460 V AC) [kVA]
21.5
27.1
31.9
41.4
Max. input current
Continuous (3x380–440 V) [A]
22
29
29
34
34
40
40
55
Intermittent (60 s overload)
(3x380–440 V) [A]
35.2
31.9
46.4
37.4
54.4
44
64
60.5
Continuous (3x441–500 V) [A]
19
25
25
31
31
36
36
47
Intermittent (60 s overload)
(3x441–500 V) [A]
30.4
27.5
40
34.1
49.6
39.6
57.6
51.7
Additional specifications
IP21, IP55, IP66 max. cable cross-
section
5)
(line power, brake, load
sharing) [mm
2
(AWG)]
2)
16, 10, 16 (6, 8, 6)
16, 10, 16 (6, 8, 6)
35,-,-(2,-,-)
35,-,-(2,-,-)
IP21, IP55, IP66 max. cable cross-
section
5)
(motor) [mm
2
(AWG)]
2)
10, 10,- (8, 8,-)
10, 10,- (8, 8,-)
35, 25, 25 (2, 4, 4)
35, 25, 25 (2, 4, 4)
IP20 max. cable cross-section
5)
(line
power, brake, motor and load sharing)
10, 10,- (8, 8,-)
10, 10,- (8, 8,-)
35,-,-(2,-,-)
35,-,-(2,-,-)
Max. cable cross-section with
disconnect [AWG (mm
2
)]
2)
16, 10, 10 (6, 8, 8)
Estimated power loss
at rated max. load [W]
4)
291
392
379
465
444
525
547
739
Weight, enclosure IP20 (lbs [kg])
26.46 [12]
26.46 [12]
51.81 [23.5]
51.81 [23.5]
Weight, enclosure IP21, IP55, 66 (lbs
[kg])
50.71 [23]
50.71 [23]
59.53 [27]
59.53 [27]
Efficiency
4)
0.98
0.98
0.98
0.98
Table 10.5 Line Power Supply 3x380–500 V AC (FC 302), 3x380–480 V AC (FC 301)
Specifications
VLT
®
AutomationDrive Instruction
Manual
MG33AM22 - VLT
®
is a registered Danfoss trademark
10-5
10
10
Содержание FC 300
Страница 1: ...MAKING MODERN LIVING POSSIBLE Instruction Manual VLT AutomationDrive FC 300 0 25 75 kW ...
Страница 2: ......
Страница 8: ...Contents VLT AutomationDrive Instruction Manual MG33AM22 VLT is a registered Danfoss trademark ...
Страница 14: ...Introduction VLT AutomationDrive Instruction Manual 1 6 MG33AM22 VLT is a registered Danfoss trademark 1 1 ...
Страница 62: ...Status Messages VLT AutomationDrive Instruction Manual 7 4 MG33AM22 VLT is a registered Danfoss trademark 7 7 ...
Страница 109: ...Index VLT AutomationDrive Instruction Manual MG33AM22 VLT is a registered Danfoss trademark 12 5 ...
Страница 110: ...www danfoss com drives MG33AM22 130R0300 MG33AM22 Rev 2013 03 12 ...