To select the alternate firmware version for the next boot:
1. Under Next Boot Firmware Version, select
Use
Alternate Version on Next Reboot
. The
alternate firmware version currently displayed will be loaded on the next boot cycle.
2. Click
Submit
.
3. Click
Reboot
to reset the switch.
Switch Configuration Files
Switch configuration settings (for example, zoning or Port Smart Settings) can be saved for
backup purposes or for loading the same configuration on multiple switches.
To save the current configuration:
1. Click
Save
to save the current switch configuration.
2. Click
OK
on the File Download dialog box.
3. Enter the directory path and file name, being sure to use a .cfg extension.
4. Click
Save
.
To load a saved configuration:
1. Under Download New Configuration File to Switch and Reboot, enter the directory path to
the .cfg file in the text box, or use the
Browse
button to navigate to the appropriate file.
2. In the Choose File dialog box, navigate to and select the appropriate file and click
OK
.
3. Click
Start
.
A message box appears confirming the download and required switch reset.
4. Click
OK
to proceed.
Restoring the Factory Default Settings
If necessary, the switch settings can be reset to their factory default values; however, the
network configuration and port type settings are retained.
To restore the factory default configuration:
1. From the Restore Configuration to Factory Default section, click
Restore
.
A message box appears confirming the request.
2. Click
OK
to restore the factory default configuration and reset the switch.