The switch may be placed on a desktop or installed in a rack.
Desktop Installation
To place the switch on a desktop:
1. Turn the switch upside down so the case bottom is facing up.
2. Install a self-adhesive pad (included) on each corner of the switch bottom approximately 1
inch from each side (prevents surface damage).
3. Turn the switch right-side up so the case bottom is facing down and place the switch on a
stable table or platform.
For information on environmental requirements, see “Operating Conditions” on page 62.
Rack Installation
Installing the switch in an equipment rack requires an optional rack mount kit (sold separately).
There are two kit variations currently available:
•
24-inch Full Rack Mount Kit (Part Number 00651382), which supports equipment rack
depths from 22 to 29 inches.
•
30-inch Full Rack Mount Kit (Part Number 00651383), which supports equipment rack
depths from 29 to 36 inches.
The rack mount kit includes all the necessary hardware and installation instructions for properly
installing a switch into an equipment rack. Contact a sales representative for more information or
assistance in purchasing a kit.
UL Guidelines for Mounting Equipment in a Rack
When installing equipment in a rack, give careful consideration to the following factors:
•
The operating ambient temperature of rack-mounted equipment must not exceed the
maximum rated ambient temperature, which is indicated in this installation guide. (See
“Operating Conditions” on page 62.)
•
The air flow clearances specified in this installation guide must be maintained within the
rack. (See “Operating Conditions” on page 62.)
•
The AC supply circuit for rack-mounted equipment must be capable of supplying the total
current specified on all the labels of the rack-mounted equipment.
•
All AC power supply connections must be properly earthed. To ensure the integrity of the
earth connection, special attention must be given to connections that are not directly
connected to the branch circuit (for example, power strips).
•
The rack-mounting hardware has been carefully selected to properly support the
equipment. Any alternate rack-mounting hardware must provide equal or superior
support.
Note:
Important safety, electromagnetic compatibility, and regulatory information is
contained in the
Vixel Safety & Regulatory Guide
. The installation and use of
this product must be in accordance with the information given in that guide.