Portavant 80 automatic
21
Revision 12/2017
8
Operating instructions
Be sure to have read and understood section 3 "Function description".
8.1
Settings via the user menu
Changing between operating modes:
Press "Menu" to open the user menu. In the first menu item, press "+" or "-" to change the
operating mode. For more information about the operating modes see section 3 (Function
description). The selection displayed is saved as soon as you press "Menu" to open the next
menu item or if you leave the display to switch off automatically after one minute.
Enabling/disabling motion detectors:
Press "Menu" again to open the menu item allowing the disabling or enabling of connected
motion detectors. Press "+" or "-" to change the selection.
Note:
Disabling the motion detectors may be useful to keep pets out of rooms during periods
of absence. Note that motion detectors can be enabled in automatic mode only. In semi-
automatic mode, the control system disables the motion detectors.
Setting the sensitivity of the Push&Go function:
Press "Menu" again to adjust the sensitivity of the Push&Go function. Press "+" or "-" to set
the travel that the door must cover during push-starting until the drive cuts in to complete the
motion to a value between 4 and 20 mm.
Note:
If you have pets trying to open the door by paw movement, increase the push travel.
Under normal conditions, the default setting (8 mm) should be retained.
Setting the opening speed:
Press "Menu" again to set the opening speed. Press "+" or "-" to select a percent value from
the list. 100% corresponds to the maximum permissible opening speed in low kinetic energy
mode according to DIN 18650/EN 16005. The opening speed can be reduced by the user as
a percentage only.
Note:
A lower opening speed reduces the impact energy should the secondary closing edge
collide with an obstacle. Verify that the door opens quickly enough so that users can pass
the door without having to slow down or wait.
Setting the closing speed:
Press "Menu" again to set the closing speed. Press "+" or "-" to select a percent value from
the list. 100% correspond to the maximum permissible closing speed in low kinetic energy
mode according to DIN 18650/EN 16005. The default setting is only 50%. The closing speed
can be increased above that value to a maximum of 100%.
Note:
During closing, there are usually no pedestrians waiting for the motion to complete.
Accordingly, a lower speed is usually not annoying. However, in most cases the primary
closing edge may collide with pedestrians passing through as the door is closing. It is
therefore recommended not to set the closing speed to more than 50%, even though 100%
are permissible in low kinetic energy mode.
Setting the Time OPEN:
Press "Menu" again to set the period that the door remains in open position in automatic
mode. Press "+" or "-" to set the period in seconds.
Switching Party mode (function) on and off:
The Party mode function can be switched on and off by pressing “Menu” again. Use “+” and
“-“ to toggle between both settings (activated/deactivated). Please note that the “activated”
setting enables Party mode as such but does not directly put the door in Party mode. To put
Содержание Portavant 80 automatic
Страница 1: ...Manual EN Gebr Willach GmbH Stein 2 53809 Ruppichteroth Germany...
Страница 33: ...Portavant 80 automatic 32 Revision 12 2017 12 2 EC Declaration of Conformity...
Страница 34: ...Portavant 80 automatic 33 Revision 12 2017 12 3 Type examination by T V...
Страница 35: ...Portavant 80 automatic 34 Revision 12 2017...
Страница 36: ...Portavant 80 automatic 35 Revision 12 2017 13 Appendix 13 1 Parts overview and designations Parts overview...