Portavant 80 automatic
10
Revision 12/2017
4
Technical data
Mains connection
Voltage supply:
100-240 V AC; 50
– 60 Hz
Mains supply stability:
+/- 10%
Circuit protection on site:
16 A
Cable type:
min. 2 x 0.75 mm², protection class 2
Power consumption without external consumers
In stand-by mode:
max. 1 W
In drive mode:
max. 60 W
Ambient conditions
Permissible ambient temperature:
0
– 40 °C
Permissible relative humidity:
< 70 %
Use in dry interior locations only. No splash water. Protection class IP 20.
Permissible door dimensions
Door weights for single-sash operation:
20 to 80 kg (200
– 800 N)
Door weights for double-sash operation:
20 to 60 kg (200
– 600 N) per sash
Caution!
Consider add-on parts such as door handles when determining door weight.
Maximum height-to-width ratio:
2.5 : 1
Intended pass-through rate
Average motion cycles per day:
approx. 150
– 200 (planning basis for several
years of operation)
Max. motion cycles per hour:
approx. 200 (extend open period, if required)
Operating sound
Operating sound of drive:
max. 55 dB (A)
(Resonances within the building structure must be checked on site and be eliminated)
Содержание Portavant 80 automatic
Страница 1: ...Manual EN Gebr Willach GmbH Stein 2 53809 Ruppichteroth Germany...
Страница 33: ...Portavant 80 automatic 32 Revision 12 2017 12 2 EC Declaration of Conformity...
Страница 34: ...Portavant 80 automatic 33 Revision 12 2017 12 3 Type examination by T V...
Страница 35: ...Portavant 80 automatic 34 Revision 12 2017...
Страница 36: ...Portavant 80 automatic 35 Revision 12 2017 13 Appendix 13 1 Parts overview and designations Parts overview...