© 2020 Vital Systems, Inc
15
Screen Settings
The THC section of this screen has Tip Voltage Reading and Analog Voltage Multiplier
The Tip Voltage displays the value of the analog reading multiplied by the value given in the Analog
voltage multiplier
The value of the Analog Voltage multiplier can be derived based on the Plasma Machine’s 30:1 or
50:1 divider.