The system hangs up during the M3 sequence
Cause
Solution
The [ArcOK] signal is not being detected
after Torch Ignition.
Check that the
[ArcOK]
input signal is enabled and
mapped to the correct digital input on the HiCON
Integra. Also, check that the ArcOK signal LED on the
ArcPro screen changes state when toggling the digital
input.
The Torch does not move toward the designated probe limit
position
Cause
Solution
The displayed coordinates have a “Work
Offset” applied.
Refrain from using the “Zero X”, Y or Z buttons and
instead use the appropriate homing routine to go back
to machine zero, or manually jog or issue a GCode move
through MDI.
Make sure that the display is showing the machine
coordinates in order to verify if a work offset is being
used. If a work offset is applied, the offset values may be
set to zero from the “View->Fixture Offsets” window.
Mach4 is not configured with the correct
unit of measurement.
Go to the Mach4 config screen and set it to use the
appropriate unit of measurement (inches or metric).
Also, check if G20 or G21 is being called from the GCode
file.