![Visonic POWERMAXCOMPLETE PANEL - Скачать руководство пользователя страница 42](http://html.mh-extra.com/html/visonic/powermaxcomplete-panel/powermaxcomplete-panel_installers-manual_1032886042.webp)
42
D-303983 PowerMaxComplete Installer's Guide
B3. Emergency Transmitter List
Tx #
Transmitter Type
Enrolled to Zone
Name of holder
1
2
3
4
5
6
7
8
9
10
B4. Non-Alarm Transmitter List
Tx #
Transmitter Type
Enrolled to Zone
Name of holder
Assignment
1
2
3
4
5
6
7
8
9
10
APPENDIX C. PGM Output Assignment
Controlled
Appliance
ON
ON
ON
ON
ON
ON
ON by Timer
ON by Zone No.
ON
by arm
HOME
by arm
AWAY
by
disarm
by
Memory
by
Delay
by
Keyfob
ON
Time
OFF
Time
a
b
c
by line
fail
APPENDIX D. Event Codes
D1. Contact ID Event Codes
Code
Definition
Code
Definition
101
Emergency
351
Telco fault
110
Fire
373
Fire detector trouble
120
Panic
380
Gas trouble
121
Duress
381
Loss of supervision
RF
122
Silent
383
Sensor tamper
123
Audible
384
RF low battery
129
Confirmed panic
393
Fire detector clean me
131
Perimeter
401
O/C by user
132
Interior
403
Auto arm
134
Entry/Exit
406
Cancel
137
Tamper/CP
408
Quick arm
139
Burglary verified
426
Door open event
151
Gas alarm
441
Armed home
154
Flood alarm
454
Fail to close
301
AC loss
455
Fail to arm
302
Low system battery
456
Partial arm
311
Battery disconnect
459
Recent close event
313
Engineer reset
570
Bypass
321
Bell
602
Periodic test report
344
RF receiver jam detect
607
Walk test mode
350
Communication trouble
641
Senior watch trouble
D2. SIA Event Codes
Code
Definition
Code
Definition
AR
AC Restore
GJ
Gas trouble restore
AT
AC Trouble
HA
Holdup Alarm (duress)
BA
Burglary Alarm
HV
Confirmed panic
BB
Burglary Bypass
LR
Phone Line Restore
BC
Burglary Cancel
LT
Phone Line Trouble
BR
Burglary Restore
OP
Opening Report
BT
Burglary Trouble /
Jamming
OT
Fail to Arm
BV
Burglary Verified
PA
Panic Alarm
BZ
Missing Supervision
QA
Emergency Alarm
CF
Forced Closing
RN
Engineer Reset
CI
Fail to Close
RP
Automatic Test
CL
Closing Report
RX
Manual Test
CP
Auto Arm
RY
Exit from Manual Test
CR
Recent Close
TA
Tamper Alarm
EA
Door Open
TR
Tamper Restore
FA
Fire Alarm
WA
Flood alarm
FT
Fire Detector Clean
WR
Flood alarm restore
FJ
Fire detector trouble
XR
Sensor Battery Restore
FR
Fire Restore
XT
Sensor Battery
Trouble
GA
Gas alarm
YR
System Battery
Restore
GR
Gas alarm restore
YT
System Battery
Trouble/Disconnection
GT
Gas trouble
YX
Service Required
Содержание POWERMAXCOMPLETE PANEL -
Страница 20: ...20 D 303983 PowerMaxComplete Installer s Guide Figure 4 4 DEFINE PANEL Flow Chart ...
Страница 25: ...D 303983 PowerMaxComplete Installer s Guide 25 Figure 4 5 Defining Communications ...
Страница 35: ...D 303983 PowerMaxComplete Installer s Guide 35 Figure 4 17 Operation Mode Configurations Flow Chart ...