30
D-303983 PowerMaxComplete Installer's Guide
The following LAN messages are reported:
Message
Description
Unit is ok
Broadband Module is functioning
correctly.
Test aborted
The diagnostic test is aborted, as
follows:
AC failure
– Broadband Module is
set to OFF mode.
Broadband
Module
has
not
completed the power-up procedure.
In this case, the installer should wait
a maximum of 30 seconds before
re-testing.
Comm. loss
The RS-232 serial interface between
the Broadband Module and the
PowerMaxComplete failed.
Rcvr Ip
missing
Receivers IP 1 and 2 settings are
missing in the PowerMaxComplete.
Cable
unplugged
The Ethernet cable is not connected
to the Broadband Module.
Check lan
config
This message appears in any of the
following cases:
Incorrect Broadband Module IP has
been entered.
Incorrect subnet mask has been
Message
Description
entered.
Incorrect default gateway has been
entered.
DHCP server failure.
Rcvr#1
UnReach.
Rcvr#2
UnReach.
Receiver 1 or 2 is inaccessible, as
follows:
Wrong receiver IP has been entered.
Receiver failure.
WAN Network failure.
Rcvr#1 UnReg.
Rcvr#2 UnReg.
The PowerMaxComplete unit is not
registered to IP receiver 1 or 2.
Broadband
Module
timeout err.
Broadband Module does not respond
to test result within 70 sec.
Invalid result
Broadband Module responds with a
result code that is not recognized by the
PowerMaxComplete.
(see figure 4.1a)
10. DIAGNOSTICS
GPRS CONN. TEST
LAN CONNECT. TEST
PLEASE WAIT...
PLEASE WAIT...
UNIT IS OK
UNIT IS OK
*
( )
*
( )
When the OK button is pressed, the test result takes
between 15 sec. to 4 mins. before it is displayed,
depending on the severity of the failure.
See par. 4.10.1 for a complete list of possible
GSM/GPRS messages and par. 4.10.2 for a
complete list of possible Broadband Module messages.
*
( )
(Perform walk test)
BATHROOM
DIAG. TESTING
FRONT DOOR
Z1 POOR
Z19 STRONG
(alternating for 5 sec.)
LIVING ROOM
Z2 OK
(alternating for 5 sec.)
Example
of test
result
display
(Each time the OK button is pressed,
the next test result is displayed)
Example
of test
result
display
Example
of test
result
display
DIAG. TESTING
WL SENSORS TEST
S1 CPU
WL SIRENS TEST
S1 CPU=STRONG
WAIT
S2 CPU
PLEASE WAIT...
S2 CPU=STRONG
WL KEYPADS TEST
K1 CPU
K1 CPU=STRONG
WAIT
K2 CPU
PLEASE WAIT...
K2 CPU=STRONG
Note
STRONG/GOOD/POOR/
“NOT OK” (with siren No.,
S1 or S2 before) is
displayed according to the
wireless siren signal
strength).
S1=siren 1. S2 = siren 2.
CPU = Control Panel Unit
= 2 way comm.
Note
STRONG/GOOD/POOR/
“NOT OK” (with keypad
No., K1 or K2 before) is
displayed according to the
wireless keypad signal
strength).
K1=keypad1 K2=keypad2
CPU = Control Panel Unit
= 2 way comm.
NON-PARTITIONING ONLY
LAN RESET OPTION
REBOOT
FACTORY DEFIN.
REBOOT: Resets the Broadband Module
FACTORY DEFIN:
Resets all LAN setting definitions (does not
reset Central Station IP definitions).
Figure 4.10 - Diagnostic Test Flow Chart