D-303983 PowerMaxComplete Installer's Guide
13
(See fig. 4.1a)
1. NEW INSTL CODE
NEW INST. CODE
INST. CODE xxxx
[code]
Figure 4.1b - Setting a New Installer Code
(see note)
By using
INSTALLER CODE
INST. CODE xxxx
NEW INST. CODE
[code]
1. NEW INSTL CODE
(see fig. 4.1a)
(see fig. 4.1a)
[code]
1. NEW INSTL CODE
NEW MASTER CODE
MASTER CODE xxxx
[code]
INST. CODE xxxx
NEW INST. CODE
By using
MASTER INSTALLER CODE
Figure 4.1c - Setting a New Installer Code
in System with Inst. & Master Inst. Codes
(see note)
Note:
Installer
Code should never be programmed as
“0000”. Doing so will lock the user out of the installer menu!
4.2 ENROLLING WIRELESS DEVICES AND KEYFOB TRANSMITTERS
4.2.1 General Guidance
The ENROLLING mode has the following sub-modes:
ENROLLING TYPE (wireless devices)
ENROLL SENSORS.
ENROLL
KEYFOB
(multi-button
CodeSecure
transmitters)
ENROLL WL 1WAY KP (wireless commander MCM-140+)
ENROLL
WL
LCD
KP
(wireless
2-way
keypad
MKP-150/151/152 or wireless 2-way keyprox MKP-160)
Note:
This sub-mode will be hidden if Partition is enabled.
ENROLL WL SIREN (wireless siren)
ENROLL PROX TAG (proximity tag)
Before beginning, gather all the devices that you intend to
enroll and make sure they all have batteries installed.
Your control panel must recognize the unique identification
code (ID) of each such device in order to supervise them,
receive their signals and respond accordingly.
Attention!
CodeSecure transmitters are mainly used for
arming/disarming and can not be enrolled to zones.
In
order to enroll to zones, use only non-CodeSecure
wireless devices.
4.2.2 Enrolling Type
Here you determine whether to enroll a wireless device by
normal transmission or by device Tamper function
(opening its cover). Options:
normal,
or
by tamper
.
4.2.3 Enroll/Delete Sensors
For PowerMaxComplete without expander module:
Magnetic contact or any other contact (not a detector) can
be enrolled in zone 29 and wireless detectors can be
enrolled in zones 01-28.
For PowerMaxComplete with expander module: Wired
detectors can be enrolled in zones 29&30 and wireless
detectors can be enrolled in zones 01-28.
Note:
Wired zones need to be enrolled in the ENROLLING
menu before they are active.
STOP
Before enrolling, the lens at the front of PIR
and dual-technology sensors should be
masked to prevent inadvertent transmission.
Make sure that magnetic contact transmitters are
together with their magnets, to prevent them from
sending alarm transmissions.
To enroll / delete wired / wireless sensors, refer to Fig. 4.2.
4.2.4 Enroll/Delete Keyfob
Transmitters
Keyfob transmitters are multi-
button wireless CodeSecure™
transmitters. Eight system users use them for better,
quicker and safer control over various system functions.
To enroll / delete 1-way or 2-way keyfob transmitters, refer
to figure 4.2.
4.2.5 Enroll/Delete Wireless
Commander
The Wireless Commander (MCM-140+) is a remote control
unit that enables the user to remotely control the system.
To enroll / delete up to 8 wireless commanders, refer to
figure 4.2 (Enroll WL 1-way KP).
4.2.6 Enroll/Delete 2-Way Keypad /
Keyprox
The 2-way keypad, type MKP-150/MKP-151/MKP-152, or
2-way keyprox, type MKP-160 enables the user to
remotely control the system and also to receive data from
the system (status, alarm and trouble data). To enroll up to
two 2-way keypads, refer to figure 4.2.
4.2.7 Enroll/Delete Wireless Siren
The wireless siren is a remote siren that is activated upon
predefined events by the PowerMaxComplete system. To
enroll / delete up to 2 wireless sirens, refer to figure 4.2.
4.2.8 Enroll/Delete Proximity Tags
Proximity tags enable authorized people to enter restricted
areas. Presenting valid proximity tag, while the system is
armed, causes the system to disarm. Presenting valid
proximity tag, while the system is disarmed, causes the
system to be armed in AWAY (optional HOME) mode. To
enroll / delete proximity tags, refer to figure 4.2.
Note:
Proximity tags are used on control panels with
installed Proximity readers (not standard on UK versions).