![Visonic POWERMAXCOMPLETE PANEL - Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/visonic/powermaxcomplete-panel/powermaxcomplete-panel_installers-manual_1032886010.webp)
10
D-303983 PowerMaxComplete Installer's Guide
Connect the power supply
output cable to the power
connector in the front
panel.
2
Safety
cover
(*)
Power
supply
unit
Power cable clamp
options
For thin
cable
For thick cable
(reversed clamp)
Insert power cable through the desired wiring
channel (see step 1), route it to the power supply
unit and connect its 2 wires to the power supply
terminal strip with screwdriver. Fasten power cable
by its clamp (see also step 2 - this clamp can be
reversed to fit thick/thin cable) and close the safety
cover.
1
T h i c k c a b l e
entry:
Pull out a
d e s ir ed w iri ng
plastic cap (1 of 4).
1
Extract cable clamp
for use in the next
step.
2
Power Connection for all Countries Except USA
Power Cable Clamp Extraction
Connect the power adapter
to the front panel power
connector.
Power Connection for USA Only
Figure 3.10 - Power Cable Connection
* Do not route wiring in this area, to enable proper closure of the control panel.
Содержание POWERMAXCOMPLETE PANEL -