D-303983 PowerMaxComplete Installer's Guide
27
4.6 GSM Auto Detection
The GSM modem auto detection feature enables
automatic enrollment of the GSM modem into the
PowerMaxComplete control panel memory. GSM modem
auto detection is activated in one of two ways: after tamper
restore and after reset (power-up or after exiting the
installer menu). This causes the PowerMaxComplete to
automatically scan GSM COM ports for the presence of
the GSM modem.
In the event that the GSM modem auto detection fails and the
modem was previously enrolled in the PowerMaxComplete
control panel, the message "Cel Rmvd Cnfrm" will be
displayed. This message will disappear from the display only
after the user clicks
. The modem is then
considered as not enrolled and no GSM trouble message will
be displayed.
Note:
A message is displayed only when the
PowerMaxComplete alarm system is disarmed.
4.7 POWERLINK Auto Detection
The POWERLINK modem auto detection feature enables
automatic enrollment of the POWERLINK modem into the
PowerMaxComplete control panel memory. POWERLINK
modem auto detection is activated in one of two ways: after
tamper restore and after reset (power-up or after exiting the
installer menu). This causes the PowerMaxComplete to
automatically scan POWERLINK COM ports for the
presence of the POWERLINK modem.
In the event that the POWERLINK modem auto detection
fails and the modem was previously enrolled in the
PowerMaxComplete control panel, the message "BBA
Remvd Cnfrm" will be displayed. This message will
disappear from the display only after the user clicks
. The modem is then considered as not
enrolled and no POWERLINK trouble message will be
displayed.
Note:
A message is displayed only when the
PowerMaxComplete alarm system is disarmed.
4.8 DEFINING OUTPUT PARAMETERS
4.8.1 Preliminary Guidance
This mode allows you:
a. Events/conditions
selection
under
which
PGM
(programmable) output will function.
b. Selection of the internal siren or STROBE light (that will
be activated according to system programming).
Note:
The PGM outputs operate on the entire alarm
system and not per partition
(in a PowerMaxComplete
Partition system
.
4.8.2 Define PGM
For the PGM output, you can select
disable, turn on
,
turn
off
or
pulse active
(turn on for predefined period, selected
by
PULSE TIME
), as follows:
BY ARM AWAY (
upon AWAY arming).
BY ARM HOME
(upon HOME arming).
BY DISARM
(upon disarming).
BY MEMORY
(activated upon registration of an alarm in
the memory, turned off upon memory clearing).
BY DELAY
(during exit / entry delays).
BY KEYFOB
(upon AUX button pressing in the keyfob
transmitter / MCM-140+
, if “
PGM
” is selected in “Define
Panel” menu, locations 17 and 18).
BY ZONES
(by disturbance in each of 3 selected zones,
irrespective of arming / disarming). If you select
toggle
,
the PGM output will be turned on upon event
occurrence in these zones and will be turned off upon
next event occurrence, alternately.
BY LINE FAIL:
PGM output is ON if telephone line is
disconnected.
BY SIREN:
this option triggers an external wired siren if
no fixed external siren output is installed.
4.8.3 Defining INT/STRB
Here you determine whether the INT output will be used for an
internal siren or for a strobe. If strobe is selected, the INT
output will be activated when an alarm occurs until the system
is disarmed and rearmed again (i.e. clearing alarm memory).
4.8.4 PGM General Definition
Here you determine the PGM LOCKOUT TIME - daytime
limits between which PGM output (that is controlled by
sensors) will be off even when the associated sensors are
triggered. To disable the lockout time, the START and
STOP times should be identical (see figure 4.8).