D-303983 PowerMaxComplete Installer's Guide
37
6.2 Replacing the Backup Battery
Replacement and first-time insertion of battery pack is
similar (see figure 3.1C).
With fresh battery pack, correct insertion and tightened
battery compartment lid, the TROUBLE indicator should
extinguish. However, the “MEMORY” message will now
blink in the display (caused
by the “tamper” alarm you
triggered when opening the battery compartment lid). Clear
it by arming the system and immediately disarming.
6.3 Fuse Replacement
The PowerMaxComplete has two internal fuses that have
automatic reset. Therefore, there is no need to replace
fuses.
When over current condition occurs, the fuse cuts off the
circuit current. Upon fault current being removed for
several seconds, the fuse is automatically reset and allows
current flow through the circuit again.
6.4 Replacing/Relocating Detectors
Whenever maintenance work involves replacement or re-
location of detectors, always perform
a full diagnostic test
according to par. 4.10.
Remember!
A "poor" signal is not acceptable, as stated at
the end of the test procedure.
7. READING THE EVENT LOG
Events are stored in the event log. You can access this log
and review the events, one by one. If the event log fills up
completely, the oldest event is deleted upon registration of
each new event.
The
date
and
time
of
occurrence
are
memorized
for
each
event.
When reading the event log, events are shown in
chronological order - from the newest to the oldest. Access
to the event log is provided by clicking the
key and
not through the installer’s menu. Reading and erasing
process of the event log is shown in the next drawing.
Oldest Event
Latest Event
LIST OF EVENTS
CODE _ _ _ _
(Enter 4-digit
installer code)
(*)
<OK TO EXIT
CLEAR EVENT LOG
<OFF> TO DELETE
(Return to normal
operation)
(**)
Figure 7 - Reading / Erasing the Event Log
*
Event is displayed in 2 parts, for example, "Z13 alarm" then "09/02/00 3:37 P". The two displays will be shown
alternately until clicking
again to move to the next event or until the end of the event log (4 minutes).
**
Applicable only if installer code is entered. Not applicable in European countries.