2.9.7
Connecting power to the router
2.9.7.1
GW7304-3G-AC
Unscrew the terminal block from the connector on the router.
Figure 9: The AC connector on the GW7304-3G-AC router
The AC cable cross section, stranded with ferrule and plastic sleeve should be 2.5mm
2
maximum or no greater than AWG 12.
Attach the neutral wire (blue) to the far left receptical of the terminal block, as shown in
the figure below.
Attach the live wire (brown) to the second left receptical on the terminal block, as shown
in the figure below.
Note: you must attach the live and neutral wires exactly as shown in the figure below.
Under no circumstance should they be plugged into any other terminals or damage to
the router may occur.
Figure 10: The AC terminal block plugged into the GW7304-3G-AC
Screw the terminal block with the wires back into the connector.
2.9.7.2
GW7304-3G-DC
Unscrew the terminal block from the connector on the router.
Figure 11: The DC connector on the GW7304-3G-DC router