A100K10652
IP DECT 6000 System Installation & Configuration Guide
Figure 6 Synchronization Chain with Secondary Sync Ways
-No. 0 is the Sync Master (may be numbered 0 to 255).
-
No. 10, No. 20, No. 30, and No. 40: Primary and secondary sync
on No. 0.
-No. 11: Primary sync on No. 10 and secondary sync on No. 21.
-No. 21: Primary sync on No. 20 and secondary sync on No. 11.
-No. 31: Primary sync on No. 30 and secondary sync on No. 41.
-No. 41: Primary sync on No. 40 and secondary sync on No. 31.
Figure 7 Synchronization Chain Layout with Secondary Sync Ways
●
No. 0
is the Sync Master (may be numbered 0 to 255).
●
Green line
: Shows the primary sync ways.
●
Red line
: Shows the secondary sync ways.