IP DECT 6000 System Installation & Configuration Guide
3.
Click the relevant base station in the list to open the Configuration
page.
4. In the
RPN
field, type the Radio Part Number of the base station.
-The Radio Part Number can be a number between 0 and 255. See
your site plan. The default value of the RPN is the base station
number. It is recommended that the number starts with 1.
5. For
Cluster
, leave as
Default
.
6. Check the
Auto sync
checkbox if you are deploying and want to find
a sync way for the first base station.
-Auto sync is only to be used in a deployment situation. When
selecting Auto sync, radio part numbers in the
Primary sync (RPN)
and
Secondary sync (RPN)
fields are not taken into consideration.
7. In the
Primary sync (RPN)
field, enter the radio part number of the
base station you want to synchronize on.
-See your site plan.
8. In the
Secondary sync (RPN)
field, enter the radio part number of
the base station, you want to synchronize on.
-See your site plan.
9. Click
Save
.
10. Click
Restart base station
to enable the configuration changes.
To check the sync state of the base station, refer to “Sync State of Base
Station”.
9.5 Checking the LED Indicator
Verify that the base station LED is lighting a steady green, indicating that
the base station is now operational.