20
A100K10652
IP DECT 6000 System Installation & Configuration Guide
4 Installing the IP DECT Server 6000
This section provides a general description of the IP DECT Server 6000
as well as information about resetting the hardware using the Reset
button on the faceplate. Before you install the equipment, ensure that a
site plan has been prepared that defines the location of the Server 6000.
4.1 Description of the Server 6000
4.1.1 Type and Part Number
The Server 6000 contains RF circuitry that comply with the local band
standards ETSI DECT and USA DECT 6.0.
Model type: IP DECT Server 6000 1.8/1.9 GHz with SIP Protocol
Part Number: 221 100 0100
4.1.2 Server 6000 Appearance and Components
The Server 6000 front cover has a LED located in the middle that
indicates the operating status of the unit.
Figure 10 Server 6000 - Front view
4.1.3 Server 6000 LED Indicators
4.1.3.1 Front Cover
The Server 6000 front cover has one LED indicator showing the faults
and failures of the device. The indicator is off when the Server 6000 is
not powered. The LED flashes when the Server 6000 initializes. The
indicator is on when the Server 6000 is operating.
Table 2 LED Indicator Description - Front Cover
LED Indicator
Meaning
Steady green
OK and idle
Slow green flashing
OK and active voice call
Fast green flashing
Active, in operation with maximum active connections (busy)
Slow red flashing
Missing base station
Fast red flashing
Error
Steady red
Reset/shutdown in progress
Steady red for 5
seconds followed by
fast red flashing
Reset to factory settings
LED