25
SW24.W
LOAD
Restore default values and loading from
memory card
Sub
menu
Description
Msg
display
DEF
Loading the default values
Waiting press OK for 5 s to load
the default values.
oooo
Note:
Loading the default values then requires the
travel to be calibrated again, LRNT flashes
on the display until (rapid or advanced)
calibration is done.
MEM
Loading the programming from
memory card
Waiting press OK for 5 s to load
the values from memory card."
oooo
Loading from memory card com-
pleted OK.
DONE
Loading from memory card error
(e.g. no card).
EMEM
PASS
Control panel protection level settings
(default = OFF)
OFF No protection
1
Protection of menus MOT, LRNT, TRV, OUT,
IN, LGC, STAT, EXP, LOAD
2
Protection of menu RAD
3
Protection from IP connection (it is not
possible to connect to the control panel from
a smartphone)
4
Protection of menus MOT, LRNT, TRV,
OUT, IN, LGC, STAT, EXP, LOAD and IP
connection
5
Protection of menu RAD and IP connection
6
Complete control panel protection
7
Protection of all board menus, IP connection
available
Note:
The password must be entered in the control panel each
time you wish to access a protected menu. If the pass-
word entered is incorrect access to the menu is denied.
EN