15
SW24.W
Menu
The control panel programming is organised into menus
and sub-menus used to access and edit the parameters
and logics of the control panel. The control panel is
equipped with the following first-level menus:
Menu Description
MOT
Motor parameters setup
LRNT Travel calibration procedure run menu
TRV
Travel parameter settings menu
OUT
Auxiliary output configuration menu
IN
Input configuration menu
LGC
Operating logic settings menu
RAD
Remote control management menu
STAT
Diagnostic and reporting menu
EXP
Expansion board management menu
LOAD Default value restore menu
PASS Protection level settings menu
Block Terminal Description
Nominal
data
SEC
T1
Secondary transformer
24 Vac
T2
MOT
21
Opening motor 1
24 V DC
80W
22
Closing motor 1
25
Opening motor 2
24 V DC
80W
26
Closing motor 2
PS
0
Accessory power supply
negative
24 V DC
500 mA
1
Accessory power supply
positive
2
Accessories positive
checked
AUX
10
Flashing light negative
24 V DC
35 W
11
Flashing light positive
18
Electrical lock negative
12 Vdc
15 VA
19
Electrical lock positive
0
Accessories negative
500 mA
A1
Configurable auxiliary
output 1
A2
Configurable auxiliary
output 2
LSW
+E
Encoder power supply
positive
12 V DC
-E
Encoder power supply
negative
E1
Motor 1 encoder signal A
E2
Motor 1 encoder signal B
E5
Motor 2 encoder signal A
E6
Motor 2 encoder signal B
ACT
99
Common inputs
NO
C1
Configurable control 1
C2
Configurable control 2
C3
Configurable control 3
C4
Configurable control 4
SAF
99
Common inputs
NC
S1
Configurable safety de-
vice 1
S2
Configurable safety de-
vice 2
S3
Configurable safety de-
vice 3
S4
Configurable safety de-
vice 4
Using the display
The control panel settings are shown on the display and can
be edited using the menu navigation buttons as shown in
the following table:
Terminal block functions
Buttons Function
Pressing
duration
OK
Switching on the display
Sub-menu entry
Confirm value change
Instanta-
neous
▲
Scroll up
Increase parameter value
Instanta-
neous
▼
Scroll down
Reduce parameter value
Instanta-
neous
ESC
Exit the menu
Cancel value change and return
to menu
Switching off the display
Instanta-
neous
▲+▼
Resetting the card
3 s
▲+ OK
Opening control
1 s
▼+ OK
Closing control
1 s
ESC +
OK
Display test (switches on each
segment of the display and points
individually in sequence)
3 s
ESC +
OK
When the board is switched on
the Firmware updating mode
starts
3 s
PP
Step-step control
Instanta-
neous
EN
Controllable actuators
Ref.
Description
EAM2
EKKO 300D linear operator 24 V 3 m 300 kg
EAM3
EKKO 400D linear operator 24 V 4 m 250 kg
EIM1
HIDDY 200D underground operator 24 V 2 m
200 kg
EIM2.24 HIDDY 350D underground operator 24 V 3,5 m
200 kg
Содержание ELVOX SW24.W
Страница 30: ...28 SW24 W...
Страница 31: ...29 SW24 W...
Страница 32: ...Viale Vicenza 14 36063 Marostica VI Italy www vimar com 49401050A0 05 1904...