16
SW24.W
All sub-menus are described in the following table:
MOT
Motor parameters
Sub
menu
Description
Values
(default)
O1
Type of actuator used
(OFF)
Warning! If set to OFF the
board performs no com-
mand !
Not set
OFF
Ekko 300/400D (EAM2/EAM3)
1
Hiddy 200D (EIM1)
2
Hiddy 350D (EIM2.24)
3
O2
Type of position control
Automatically set with the choice
of actuator. You are advised not
to change the setting given by the
type of actuator.
(3)
Virtual encoder:
the control
panel calculates the gate position
using the electric motor operating
parameters
2
Encoder
EAM2, EAM3, EIM1
3
O3
Type of limit switch on opening
Automatically set with the choice
of actuator. You are advised not
to change the setting given by the
type of actuator.
(OFF)
No limit switch on opening:
the
electric motor stops at the end of
the working time
OFF
Stop limit switch on opening:
the limit switch stops the motor
1
Limit switch in proximity open
-
ing:
the limit switch allows the
manoeuvre to continue at the
approach speed set until it detects
the mechanical stop
2
O4
Type of limit switch on closing
Automatically set with the choice
of actuator.
You are advised not to change
the setting given by the type of
actuator.
(OFF)
No limit switch on closing:
the
electric motor stops at the end of
the working time
OFF
Stop limit switch on closing:
the
limit switch stops the motor
1
Limit switch in proximity clos
-
ing:
the limit switch allows the
manoeuvre to continue at the
approach speed set until it detects
the mechanical stop
2
LRNT
Motor travel calibration procedure
LRNE
Rapid travel calibration.
The calibration is done fully automatically
and sets:
- The slowdown in opening at 20% of the
total travel
- The slowdown in closing at 20% of the total
travel
- Offset in opening at 3 s and in closing at 6 s
- Pedestrian position at 30% leaf 1
Button Msg on
display
Phase description
-
PP
Wait for start of calibration
procedure
PP
CL 2
When button pressed: mo-
tor 2 closing and search for
closing stop
-
CL 1
Motor 1 closing and search
for closing stop
-
OP 1
Motor 1 opening travel
measurement and search
for stop
-
OP 2
Motor 2 opening travel
measurement and search
for stop
-
CL 2
Motor 2 closing travel
measurement
-
CL 1
Motor 1 closing travel
measurement
-
OPC1
Motor 1 opening current
curve reading
-
OPC2
Motor 2 opening current
curve reading
-
CLC2
Motor 2 closing current
curve reading
-
CLC1
Motor 1 closing current
curve reading
-
END
End of procedure
LRNA
Advanced travel calibration.
The calibration allows the installer to choose:
- Slowdown position in opening and closing
- Offset for opening and closing
- Pedestrian opening position leaf 1
Button Msg on
display
Phase description
-
PP
Wait for start of calibration
procedure
PP
CL 2
When button pressed:
motor 2 starts closing and
searches for closing stop
-
CL 1
Motor 1 starts closing and
searches for closing stop
PP
OP 1
Start opening motor 1
When button pressed:
slowdown start position on
opening setting.
PP
OP 1
When button pressed end
of travel position setting or
continuation to the stop.
Note:
O2, O3, O4 are automatically set with the choice of actua-
tor. You are advised not to change the setting given by the
type of actuator.