8.2 Key to display messages
i
Address
c
Delete Remote Controls
p
Programming
s
u
Supervision
u
All
s e
Signal strength detected
i
Install contacts and detectors
--
Ok
i
Install Remote Controls
c a
Delete
c
Delete contacts and detectors
e
Error
9. Operations on radio frequency detectors
As explained above, the interface can have 8 or 16 radio inputs to be set during configuration; the relationship
between these inputs and the alarm zones in the control panel depends on the addresses assigned to the inter-
faces 01729 and any input expansion modules 01709 and 01704 that may be present.
9.1 Saving:
a. Set the
DIP-switches 1
and
2
to
ON
; the display will show
i
(Installing Devices).
b. Press the
SELECT
button to scroll through the free addresses on which to pair the devices.
c. Run the procedure for installing the device (refer to its installer sheet).
d. If saving is successful, the display will show the next free address for a new acquisition.
e. At the end, set the
DIP-switches 1
and
2
back to
OFF
.
Caution:
If the display shows
E
, it means there has been an error when saving; in which case, press the
SELECT
button and run the procedure again.
By-alarm
Operations on radio frequency detectors