6
The LEDs have the following meanings:
-
1
: Red LED -> tamper zone.
-
2
: Blue LED -> zone under supervision.
-
3
: Amber LED -> battery fault zone.
-
4
: Red LED -> zone in alarm status.
-
5
: Red LED -> signalling transmission of a data packet from the interface to a device.
-
6
: Green LED -> signalling receiving a data packet from a device to the interface.
5. Configuring the radio interface
The radio interface integrates completely, considering the different possibilities, with all the By-alarm control panels
01700 and 01703.
5.1 Addressing
To be recognized, the interfaces connected to the control panel need to be appropriately addressed.
N.B. The address to be associated with the interface must be different from the addresses previously
assigned to other interfaces 01729 or input expansion modules 01709 and 01704. The addresses must
be assigned in a sequential manner, ie assigning ID=1 to the first device, 2 to the second one, and so on.
To address the interfaces carry out the following procedure:
a. Power up the interface; the display will show the symbol
--
.
b. Set
DIP-switch 5
to
ON
and the display will show
(Address).
c. Press the
SELECT
button to display the currently programmed address.
d. Press the
PROG
button and the display will show
P
(programming).
e. Press the
SELECT
button to change the value of the address (from 01 to 32). The highest address that can
be assigned depends on the type of control panel installed (see the relevant manuals).
f. Press the
PROG
button to confirm the address, the display will show
.
g. At the end, set
DIP-switch 5
back to
OFF
.
By-alarm