Disassembly
32
©2010 Viking Preferred Service
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.
Hinge Receiver Removal
Condition Requirements:
Door Assembly Removed
Side Panel Removed
1. Remove screws, trim, and pull interior side panel
back to access hinge receiver.
2. Pull back insulation to access hinge receiver.
3. Remove screw and hinge receiver from range.
4. Reverse procedure for installation.
Back Panel Removal
Condition Requirements:
Rear of Range Accessed
Note:
VGIC536 shown. Other models may have
different back panels.
1. Remove screws and back cover from back panel.
2. Remove screws and back panel from range.
3. Reverse procedure for installation.
Terminal Block Removal
Condition Requirements:
Back Panel Removed
1. Remove screws and cover from range.
2. Mark and disconnect connectors from terminal block.
3. Remove screws and terminal block from range.
4. Reverse procedure for installation.