Disassembly
28
©2010 Viking Preferred Service
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.
Direct Spark Module Accessed
Condition Requirements:
None
1. Remove burner grates, caps, bowls, and grate
support from right side of the range.
2. Remove screw and position burner assembly away
from cover.
3. Remove screws and cover from range.
4. Reverse procedure for installation.
High Limit Switch Removal
Condition Requirements:
Direct Spark Module Accessed
1. Mark and disconnect wires from high limit switch.
2. Remove screws and high limit switch from bracket.
3. Reverse procedure for installation.
Direct Spark Module Removal
Condition Requirements:
Direct Spark Module Accessed
1. Mark and disconnect four connectors from direct
spark module.
2. Remove four screws and direct spark module from
range.
3. Reverse procedure for installation.