Troubleshooting
©2010 Viking Preferred Service
19
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.
Spark Module Test
Surface Burner Igniter Will Not Spark
1. Check for and remove any foreign objects/soil
buildup around the igniter and operate burner again.
2. If still inoperative, disconnect power to the range.
3. Access the oven control panel.
4. Disconnect the wire harness from the inoperative
spark module.
5. Reconnect power and test for 120 VAC from the
black to the white wire.
6. If 120 VAC is present, disconnect power and
reconnect wire harness. (If no 120 VAC, check
wiring.)
7. Remove the grate and burner cap.
8. Disconnect the black wire from the back of the spark
module.
9. Check for 0 ohms between the black wire and the
metal top of the igniter. (If open, replace wire.)
10. If 120 VAC is present in step 5 and the black igniter
wire has continuity, replace the spark module.
RTD Characteristics
Proper diagnostics of the RTD (Resistance Temperature
Detector) will eliminate unnecessary replacement.
The RTD is designed to change resistance as the
temperature in the oven cavity changes. As the
temperature increases, so does the resistance. At 75°F,
the resistance should be approximately 1090
Ω
.
To test the RTD, locate the 2-Pin Molex connector. The
connector is located on the oven control.
Unplug the connector and check between the yellow
wires. At ambient temperature you should read around
1090 ohms (±10%). An open reading (
∞
) indicates either
a broken wire or open RTD. Finally, test each wire to
ground to check for a pinched wire to the oven frame.
If the RTD resistance is within the specifications given
it is not necessary to replace the RTD. If the RTD test
resistance is within specifications and the consumer
is having erratic oven temperatures, please call Viking
Technical support (1-800-914-4799) for assistance.
RTD (Resistance Temperature Detector)
Temperature (°F)
Resistance (Approximate)
50
1038
75
1090
100
1143
200
1350
300
1553
350
1654
400
1754
450
1852
500
1950
550
2047
600
2153
650
2238
700
2332
750
2425
800
2518
850
2609
900
2700