background image

26

When set to “Enabled” the Remote Access Operation Commands (

0 to 

1) to Un-Latch or Latch the relay are enabled.

These can be entered on a Inbound call after the access code is dialed (if programmed).

When set to “Disabled” the Remote Access Operation Commands (

0 to 

1) to Un-Latch or Latch the relay are

disabled. Disabling the Latch commands can be useful in applications where you want to eliminate the possibility of
inadvertently entering a latch command leaving a gate open/closed, etc. 

Factory Setting:

Enabled

18. Relay Latch Commands

The Speaker volume can be set from 0 - 9,  0 = lowest volume setting, 9= highest volume setting. Adjusting this will set
the volume level for incoming/outgoing Phone calls.  

Factory Setting:

3

21. Speaker Volume

20. Speaker Mode 

The Speaker Mode can be set to one of the following three modes. 

Factory Setting: 

ON

OFF/Silent Monitoring Mode:

In the “OFF” mode the speaker is disabled at all times. However, the speaker can be

enabled after communication has been established by entering touch tone command “

9#

”. The speaker will remain on for

the duration of the call.

ON (factory setting):

In the “ON” mode the speaker is enabled during In-bound and Out-bound calls. 

OFF Until Answered: 

In the “OFF Until Answered” mode the speaker will remain silent during dialing and will not turn

on until the called party has answered

With Alternate Switch Action Enabled the CALL button alternately connects and disconnects calls. With Alternate Switch
Action Disabled the CALL button connects calls only. Pressing the button again after the call has been initiated will not
terminate the call.  

Factory Setting:

Enabled

19. Alternating Switch Action (Panic Button Mode)

When set to Ring or Ring with AGC, The 

1600-IP Series Phone

will output a loud ring when it is called. The level can

be adjusted from 0 - 9. 

Factory Setting:

5

22. Ring Volume

The relay activation tone is a buzzing sound that is heard from the speaker when the door strike relay is activated.
After the called party enters the correct relay activation command, the called party will hear 2 short confirmation beeps
and the entry phone will output a buzzing sound (relay activation tone) while the door strike relay is activated. The tone
(buzz) length will match the relay activation time up to a maximum of 5 seconds. The tone (buzz) can be programmed
to three different volume settings 1 = Low, 2 = Medium, 3 = High or it can be disabled.

Factory Setting:

3

17. Relay Buzz Volume

The one or two digit code stored in the Relay Activation Command is the touch tone command that the person being
called must enter on their phone in order to momentarily activate the relay to control a doorstrike, mag-lock, gate
controller, or other device. The code can contain the characters 0 - 9, # or 

. The code cannot match a relay latching

command (

1, 

0). The code must be entered while the remote phone is communicating with the Speaker phone.

Factory Setting:

15. Relay Activation Command 

The value stored in the Relay Activation Time is the amount of time the relay will be energized after a correct momentary
touch tone command is entered. This number can range from 0.5 - 99 seconds. This also affects timing in Doorbell
Mode. 

Factory Setting:

5 seconds

16. Relay Activation Time 

Содержание 1600-IP Series

Страница 1: ...95 non condensing Humidity EWP Products Up to 100 Audio Codecs G711u G711a G722 Network Compliance IEEE 802 3 af PoE SIP 2 0 RFC3261 100BASE TX with auto cross over Regulatory Compliance CE FCC Part 1...

Страница 2: ...Express CUCME Elastix epygi QX200 Freeswitch Grandstream Interactive Intelligence iPECS Ericsson LG Iwatsu ECS Kamailio Mitel 3300 NEC OfficeSIP OpenSIPS Panasonic with SIP Extension Card PolyCom SIP...

Страница 3: ...14 gauge marine grade 316 stain less steel with 4 brushed finish T 10 Torx Security Screws Model E 1600 22 IP HxWxD 5 0 x 5 0 x 2 25 Mounting Flush mount in a standard double gang electrical box or s...

Страница 4: ...Protocol is an Internet protocol standard that specifies a way for programs to manage the real time transmission of multimedia data over either unicast or multicast network services Server A computer...

Страница 5: ...itch optional Speaker Microphone MAC Address Label The MAC address is a unique 12 digit number used by routers to send network traffic to the correct IP address PoE LAN Port 10 100 PoE Class 1 4 Watts...

Страница 6: ...aterial 062 16 gauge steel Finish E 1600 IP Red powder paint E 1600 45 IP Yellow powder paint E 1600 60 65 IP Blue powder paint Connections Gel filled butt connectors Mounting Surface mount to walls p...

Страница 7: ...ting Flush mount in elevator cabs ATMs stairwells hallways etc Suggested Hardware 6 8 x 3 4 flat head phillips sheet metal type A screws not included Optional Enhanced Weather Protection EWP Available...

Страница 8: ...aled per IP67 Dimensions 183mm x 149mm x 39mm 7 22 x 5 36 x 1 55 Material 14 gauge Marine grade 316 brushed stainless steel panel Shipping Weight 1 36 kg 3 lbs Connections Gel filled butt connectors M...

Страница 9: ...faceplate and push button switches sealed per IP67 Laser Etched Graphics Note The black plastic rough in box part 259576 may be purchased separately Example Mounting boxes to studs before the walls a...

Страница 10: ...nced Weather Protection EWP The optional EWP products feature foam rubber gaskets and boots sealed connections gel filled butt connectors as well as urethane or thermal plastic potted circuit boards S...

Страница 11: ...th and or using a rough in box with inadequate depth can apply force to the circuit board causing physical damage Important When warm air comes in contact with cold surfaces such as outside walls and...

Страница 12: ...t included Peel paper liner and adhere gasket to back of panel centering over mounting holes Caution For rough surfaces ie brick stucco etc additional caulking may be required Optional VE 5x5 Surface...

Страница 13: ...15 0 19 EWP 3 50 3 58 EWP 3 20 2 0 2 04 EWP 0 63 0 67 EWP 1 5 2 63 2 71 EWP Mylar Speaker Dimensions Speaker Gasket EWP only Standard Mic Mounting Boot Glue or screw directly behind 0 04 0 125 diamete...

Страница 14: ...R24 RL1 C58 R18 C17 R39 R50 R54 R65 R11 R32 R12 R34 R53 J3 J3 J3 J3 L9 C68 CR3 XTAL 2 TPG Z11 Z9 CR4 CR1 C C25 5 C37 7 c35 C5 L12 L11 L10 L8 R19 Z14 Z7 Z15 Z8 C59 R55 R58 L Z13 XTAL4 XTAL1 XTAL3 C55 5...

Страница 15: ...nel Remove backing and adhere gasket to front panel of the E 1600 55 IP centering over speaker and microphone holes as shown Red LED anode Black LED cathode Note If you do not want to use the LED tuck...

Страница 16: ...IP67 Push for Help Button Info Button available on model E 1600 TP2 IP EWP E 1600 TP IP EWP E 1600 TP2 IP EWP Dimensions 241mm x 299mm x 51mm 9 5 x 11 75 x 2 Shipping Weight 2 9 kg 6 4 lbs Mounting F...

Страница 17: ...e and push button switch sealed per IP67 Push for Help Button E 1600 GT IP EWP Dimensions 254mm x 305mm x 51mm 10 0 x12 0 x2 Shipping Weight 2 9 kg 6 4 lbs Mounting Flush mount to GAI TRONICS towers w...

Страница 18: ...enter E 1600 IP in the search box 2 Click E 1600 IP in the search results 3 Scroll down the page to Downloads click IP Programming Software 4 Install the programming software by saving or opening the...

Страница 19: ...ing you to trouble shoot the failure A Connect Disconnect Open the Viking IP Programming software on the PC and the start screen shown below will appear Any Viking IP phones that are connected to the...

Страница 20: ...ings tab Step 6 Select the appropriate value Static IP Settings or DHCP for Set Unit IP Address via Note changing the IP address will cause you to have to reconnect to the unit Enter the values for th...

Страница 21: ...sconnecting the LAN Cable RJ45 plug Step 2 Press and hold the Call button then reconnect the LAN Cable RJ45 plug Step 3 Continue to hold Call button until you hear 2 beeps approximately 6 seconds Then...

Страница 22: ...Microphone Volume 0 9 0 Auto factory set to 5 23 27 Talk Listen Delay VOX 0 1 0 9 seconds factory set to 0 5 seconds 24 27 In Band Audio Call Progress Enabled Disabled factory set to Enabled 25 27 In...

Страница 23: ...is not required leave this field blank 2 SIP Server 1 Unit Name Up to a 31 character unit name can be assigned to the 1600 IP Series Phone being programmed Programming Features When registered to a S...

Страница 24: ...ode Simply call the 1600 IP Series Phone set to auto answer auto answer secure the unit will automatically answer the line and output one beep You then enter the programmed 1 6 digit access code 2 bee...

Страница 25: ...ll to or from the Emergency Entry phone This mode is useful for turning on IR flood lights VoIP phones with cameras etc Doorbell Mode When programmed for Doorbell Mode the relay will momentarily activ...

Страница 26: ...nly Pressing the button again after the call has been initiated will not terminate the call Factory Setting Enabled 19 Alternating Switch Action Panic Button Mode When set to Ring or Ring with AGC The...

Страница 27: ...Ring No Answer limit or touch tone to hang up Factory Setting 3 minutes 29 Call Length Timeout This feature selects switching time between talk and listen modes VOX switching time The Talk Listen Del...

Страница 28: ...e secure options for auto answer require the callers to dial the access code in order to transmit a page activate the relay or activate the optional RC 4A relays Factory Setting Auto Answer Disabled I...

Страница 29: ...erent modes Factory Setting Entry Phone OFF Mode Useful for silent monitoring applications In this mode the LED will not light during normal operation It will only light blink if it cannot register wi...

Страница 30: ...39 IP Firmware If new 1600 IP Series Phone firmware is available after opening the programming software a pop window will come up asking you if you would like to update firmware An alternative method...

Страница 31: ...know the location of the emergency call by either the voice announcement or by decoding the touch tone I D number Once the Call Connected LED is on the key can be used to force the phone to hang up B...

Страница 32: ...post single gang box or a VE GNP gooseneck pedestal Note The VE 3x5 is not compatible with the VE GNP pedestals and is not available in stainless steel The VE 3x5 is designed to be used with the E 40...

Страница 33: ...voltage automatic battery disconnect to prevent deep cycling battery mounting hardware and 4 optional Chevron arrows with mounting templates included ARS TB100 6 wide x 9 tall Tactile Sign with 0 031...

Страница 34: ...in the workmanship or materials under normal use and service for a period of two years from the date of purchase from any authorized Viking distributor If at any time during the warranty period the pr...