Troubleshooting

If the unit cannot register with the programmed SIP server, the LED will blink on and off every two seconds, and three error
beeps will be heard every 30 seconds until communication is restored. This alerts a potential user of a problem with the
device that will prevent an emergency phone call from being made.

You may silence the error beeps, per instance, by pressing and holding the HELP/CALL button for 5 seconds or by clicking
the “Mute Alarm Until Next Failure” button in the Viking IP Programming Software (see section 

B

on page 19). The error

beeps automatically re-enable once the unit is registered, to alert of any new problems that arise.

Operation

A.  “HELP” / “CALL” Button

When the “

HELP

” / “

CALL

” button is pressed, the 

1600-IP Series

phone dials a pre-programmed telephone number. The Call

Connected LED momentarily flashes during dialing. In the event the line is busy or there is a ring-no-answer, the unit can be
programmed to call additional phone numbers.

The phone then cycles through up to 5 pre-programmed emergency numbers until the call is answered. When the call is answered,
the digital voice announcer will automatically play to identify the location of the emergency call. The phones are factory programmed
to play the announcement once, and then automatically light the “Call Connected” LED to show that handsfree communication to
emergency personnel is established. The 

key will send the I.D. number (if programmed), and play the announcement again. The

distant party will know the location of the emergency call by either the voice announcement or by decoding the touch tone I.D. number.
Once the “Call Connected” LED is on, the # key can be used to force the phone to hang-up.

B.  “INFO” Button (E-1600-20/22/52/53-IP)

When the “

INFO

” button is pressed (

1600-20/22/52/53-IP 

only), the phone goes off-hook and dials the first “

INFO

” phone number

programmed.  If a busy signal is detected or the call goes unanswered, the phone will cycle through all five “

INFO

” phone numbers

until the call is answered or lap counter is met. When answered, handsfree communication is established. 

Note:

The voice

announcement is for 

Emergency/Help

calls only and will not play on a call initiated from the “

INFO

” button.

C.  Remote Access Operation Commands

Feature

Tone Tone
Command

Description

Activate

Relay

or

___ ___

Momentarily activate relay (1 or 2 digits, factory set to 

).

Un-Latch

Relay

0

Un-latch* (deactivate) the relay.

Latch
Relay

1

Latch* (continuously activate) the relay.

Disconnect

#

Disconnects or forces the emergency phone to hang up.

Send ID and

Play Message

Send I.D. number (if programmed) and plays the announcement.

* Note: 

Latching commands must be enabled (

6

) in programming.

The following commands can be entered after answering an inbound call from the emergency phone. The commands can also be
entered on an outbound call to the emergency phone. After the emergency phone auto answers the call, two beeps will be heard. If
the access code has been disabled, you can now enter the Remote Access Operation Commands below. If an Access code has been
programmed, enter the Access code digits. With the correct code entered, two beeps will be heard and you can now enter the Remote
Access Operation Commands below.

Содержание 1600-IP Series

Страница 1: ...95 non condensing Humidity EWP Products Up to 100 Audio Codecs G711u G711a G722 Network Compliance IEEE 802 3 af PoE SIP 2 0 RFC3261 100BASE TX with auto cross over Regulatory Compliance CE FCC Part 1...

Страница 2: ...Express CUCME Elastix epygi QX200 Freeswitch Grandstream Interactive Intelligence iPECS Ericsson LG Iwatsu ECS Kamailio Mitel 3300 NEC OfficeSIP OpenSIPS Panasonic with SIP Extension Card PolyCom SIP...

Страница 3: ...14 gauge marine grade 316 stain less steel with 4 brushed finish T 10 Torx Security Screws Model E 1600 22 IP HxWxD 5 0 x 5 0 x 2 25 Mounting Flush mount in a standard double gang electrical box or s...

Страница 4: ...Protocol is an Internet protocol standard that specifies a way for programs to manage the real time transmission of multimedia data over either unicast or multicast network services Server A computer...

Страница 5: ...itch optional Speaker Microphone MAC Address Label The MAC address is a unique 12 digit number used by routers to send network traffic to the correct IP address PoE LAN Port 10 100 PoE Class 1 4 Watts...

Страница 6: ...aterial 062 16 gauge steel Finish E 1600 IP Red powder paint E 1600 45 IP Yellow powder paint E 1600 60 65 IP Blue powder paint Connections Gel filled butt connectors Mounting Surface mount to walls p...

Страница 7: ...ting Flush mount in elevator cabs ATMs stairwells hallways etc Suggested Hardware 6 8 x 3 4 flat head phillips sheet metal type A screws not included Optional Enhanced Weather Protection EWP Available...

Страница 8: ...aled per IP67 Dimensions 183mm x 149mm x 39mm 7 22 x 5 36 x 1 55 Material 14 gauge Marine grade 316 brushed stainless steel panel Shipping Weight 1 36 kg 3 lbs Connections Gel filled butt connectors M...

Страница 9: ...faceplate and push button switches sealed per IP67 Laser Etched Graphics Note The black plastic rough in box part 259576 may be purchased separately Example Mounting boxes to studs before the walls a...

Страница 10: ...nced Weather Protection EWP The optional EWP products feature foam rubber gaskets and boots sealed connections gel filled butt connectors as well as urethane or thermal plastic potted circuit boards S...

Страница 11: ...th and or using a rough in box with inadequate depth can apply force to the circuit board causing physical damage Important When warm air comes in contact with cold surfaces such as outside walls and...

Страница 12: ...t included Peel paper liner and adhere gasket to back of panel centering over mounting holes Caution For rough surfaces ie brick stucco etc additional caulking may be required Optional VE 5x5 Surface...

Страница 13: ...15 0 19 EWP 3 50 3 58 EWP 3 20 2 0 2 04 EWP 0 63 0 67 EWP 1 5 2 63 2 71 EWP Mylar Speaker Dimensions Speaker Gasket EWP only Standard Mic Mounting Boot Glue or screw directly behind 0 04 0 125 diamete...

Страница 14: ...R24 RL1 C58 R18 C17 R39 R50 R54 R65 R11 R32 R12 R34 R53 J3 J3 J3 J3 L9 C68 CR3 XTAL 2 TPG Z11 Z9 CR4 CR1 C C25 5 C37 7 c35 C5 L12 L11 L10 L8 R19 Z14 Z7 Z15 Z8 C59 R55 R58 L Z13 XTAL4 XTAL1 XTAL3 C55 5...

Страница 15: ...nel Remove backing and adhere gasket to front panel of the E 1600 55 IP centering over speaker and microphone holes as shown Red LED anode Black LED cathode Note If you do not want to use the LED tuck...

Страница 16: ...IP67 Push for Help Button Info Button available on model E 1600 TP2 IP EWP E 1600 TP IP EWP E 1600 TP2 IP EWP Dimensions 241mm x 299mm x 51mm 9 5 x 11 75 x 2 Shipping Weight 2 9 kg 6 4 lbs Mounting F...

Страница 17: ...e and push button switch sealed per IP67 Push for Help Button E 1600 GT IP EWP Dimensions 254mm x 305mm x 51mm 10 0 x12 0 x2 Shipping Weight 2 9 kg 6 4 lbs Mounting Flush mount to GAI TRONICS towers w...

Страница 18: ...enter E 1600 IP in the search box 2 Click E 1600 IP in the search results 3 Scroll down the page to Downloads click IP Programming Software 4 Install the programming software by saving or opening the...

Страница 19: ...ing you to trouble shoot the failure A Connect Disconnect Open the Viking IP Programming software on the PC and the start screen shown below will appear Any Viking IP phones that are connected to the...

Страница 20: ...ings tab Step 6 Select the appropriate value Static IP Settings or DHCP for Set Unit IP Address via Note changing the IP address will cause you to have to reconnect to the unit Enter the values for th...

Страница 21: ...sconnecting the LAN Cable RJ45 plug Step 2 Press and hold the Call button then reconnect the LAN Cable RJ45 plug Step 3 Continue to hold Call button until you hear 2 beeps approximately 6 seconds Then...

Страница 22: ...Microphone Volume 0 9 0 Auto factory set to 5 23 27 Talk Listen Delay VOX 0 1 0 9 seconds factory set to 0 5 seconds 24 27 In Band Audio Call Progress Enabled Disabled factory set to Enabled 25 27 In...

Страница 23: ...is not required leave this field blank 2 SIP Server 1 Unit Name Up to a 31 character unit name can be assigned to the 1600 IP Series Phone being programmed Programming Features When registered to a S...

Страница 24: ...ode Simply call the 1600 IP Series Phone set to auto answer auto answer secure the unit will automatically answer the line and output one beep You then enter the programmed 1 6 digit access code 2 bee...

Страница 25: ...ll to or from the Emergency Entry phone This mode is useful for turning on IR flood lights VoIP phones with cameras etc Doorbell Mode When programmed for Doorbell Mode the relay will momentarily activ...

Страница 26: ...nly Pressing the button again after the call has been initiated will not terminate the call Factory Setting Enabled 19 Alternating Switch Action Panic Button Mode When set to Ring or Ring with AGC The...

Страница 27: ...Ring No Answer limit or touch tone to hang up Factory Setting 3 minutes 29 Call Length Timeout This feature selects switching time between talk and listen modes VOX switching time The Talk Listen Del...

Страница 28: ...e secure options for auto answer require the callers to dial the access code in order to transmit a page activate the relay or activate the optional RC 4A relays Factory Setting Auto Answer Disabled I...

Страница 29: ...erent modes Factory Setting Entry Phone OFF Mode Useful for silent monitoring applications In this mode the LED will not light during normal operation It will only light blink if it cannot register wi...

Страница 30: ...39 IP Firmware If new 1600 IP Series Phone firmware is available after opening the programming software a pop window will come up asking you if you would like to update firmware An alternative method...

Страница 31: ...know the location of the emergency call by either the voice announcement or by decoding the touch tone I D number Once the Call Connected LED is on the key can be used to force the phone to hang up B...

Страница 32: ...post single gang box or a VE GNP gooseneck pedestal Note The VE 3x5 is not compatible with the VE GNP pedestals and is not available in stainless steel The VE 3x5 is designed to be used with the E 40...

Страница 33: ...voltage automatic battery disconnect to prevent deep cycling battery mounting hardware and 4 optional Chevron arrows with mounting templates included ARS TB100 6 wide x 9 tall Tactile Sign with 0 031...

Страница 34: ...in the workmanship or materials under normal use and service for a period of two years from the date of purchase from any authorized Viking distributor If at any time during the warranty period the pr...

Отзывы: