VIKING TECHNICAL SUPPORT 1.800.908.0884
3 9
TROUBLESHOOTING
LCD Display References
LCD MSG
Meaning
Page 41
TS Ref #s
RED CONN
UNPLUGED
The Motor Connector is not plugged into the red Open Left or Open Right
socket at the control board. (pg 3, 22)
23
Multi Meter Displays
MOT AMP
__._ A
This is the motor current amperage during operation.
MOT VOLT
__._ VDC
This is the actual motor voltage during operation.
AC VOLT
__._ VAC
This is the actual low voltage AC to the Control Board from the
transformer.
CHARGE
__._ VDC
Indicates the charging voltage to the batteries, if the Battery Switch is in
the OFF position.
BAT VOLT
__._ VDC
Indicates battery voltage, if the AC power is discontinued to the Control
Board.
Board Settings Messages
Speed
__
%
Shows the percentage of speed set by the Speed adjustment on the control
board. (pg 25)
OVERLAP
_._ SEC
Shows the number of seconds set by the Overlap Adjustment on the
control board.
ODS SENS
___
%
Shows the force setting selected to trip the obstruction sensor. (pg 25, 27)
TIMER
__ SEC
Shows the amount time set or remaining to hold the gate at the Open Limit
position, before the gate starts to close. (pg 25)
HEATER
CLS OFF
The Integrated Heater has been disabled for the Closed Limit. (pg 28)
HEATER
CLS ON
The Integrated Heater has been enabled to turn on at the Close Limit
position (pg 28)
“ACTIVE”
will be displayed while it is heating.
HEATER
OPN OFF
The integrated Heater has been disabled for the Open Limit. (pg 28)
HEATER
OPN ON
The Integrated Heater has been enabled to turn on at the Open Limit
position (pg 28)
“ACTIVE”
will be displayed while it is heating.
SOLAR
MODE OFF
The Solar Mode feature is turned OFF. (pg 21, 45)
SOLAR
MODE ON
The Solar Mode feature is turned ON. (pg 21, 45)