background image

 

 

 

PK300DC/PK350DC   

Swing Gate Opener 

User Manual

 

 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for PK300DC

Page 1: ...PK300DC PK350DC Swing Gate Opener User Manual...

Page 2: ...three button mode please refer to the instructions of the remote control in accordance with the actual gate opener type The indicator light on the remote control unit will flicker when the button on i...

Page 3: ...antity 1 Main engine 2 2 Manual release bar 1 3 A B C D A B C D Remote control 2 4 Control box 1 5 Wall bracket 4 6 Front mounting bracket 2 7 Connecting bracket 2 8 Mounting screw short 2 9 Mounting...

Page 4: ...20V 50Hz 110V 60Hz Motor power 80W 80W Gate moving speed 18 22 second per 90 approx 18 22 second per 90 approx Max single leaf weight 300Kg 300Kg Max single leaf length 2 5M 3 0M Max piston stroke 34c...

Page 5: ...s than 2 5m 3m The drive mode adopts the worm and worm gear to combine the screw rod transmission This gate opener must be installed inside the enclosure or yard for protection 4 1 Installation drawin...

Page 6: ...5 190 970Max 620Min 104 PK300DC 190 1370Max 820Min 104 PK350DC Figure 2...

Page 7: ...nting height is about 300 800mm from the ground and make sure there are reliable fixed points for mounting brackets Cable In order to ensure the normal operation of the door opener and protect the cab...

Page 8: ...cks infrared sensor alarm lamp external button switch and other external equipment please increase corresponding the embedded wire and the sectional area of electric lock cable core shall not be lower...

Page 9: ...the installation of screws and then manually adjust the telescopic arm to the appropriate length and finally fix the telescopic arm connector and the front mounting bracket with the installation screw...

Page 10: ...be installed installed L K L 620 5 L 620 5 K 620 340 620 340 A B Figure 8 100 110 120 130 140 150 160 170 180 190 200 100 110 120 130 140 150 160 170 180 190 200 Max 90 Max 100 Max 110 Max 120 mm mm...

Page 11: ...by by installer installer Note Note Limit Limit stopper stopper must must be be installed installed Figure 10 100 110 120 130 140 150 160 170 180 190 200 100 110 120 130 140 150 160 170 180 190 200 M...

Page 12: ...installed Figure 12 100 120 140 160 180 200 220 240 260 280 300 100 120 140 160 180 200 220 240 260 280 300 Max 90 mm mm A B Max 100 Max 110 Max 120 Figure 13 Note Value B must be close to or equal t...

Page 13: ...d by by the the users users themselves themselves Note Note Limit Limit stopper stopper must must be be installed installed Figure 14 Max 120 mm mm B A Max 110 Max 100 Max 90 100 120 140 160 180 200 2...

Page 14: ...in figure 8 12 Before installing the main engine make sure that the main engine and components are in good mechanical performance and that the door can be operated manually One control unit can contr...

Page 15: ...14 4 3 5 Control board wiring Figure 17 1 Antenna 2 Antenna s shield 3 Start input NO It completely opens the gate 4 Pedestrian start in NO It opens just motor 2 5 Common...

Page 16: ...Waiting a closing command inhibits closing During closing reverses motor direction for 1 second If not used left unconnected 10 Common 11 Stop input NC It always stops motors and blocks control unit...

Page 17: ...he control unit during working times programming This fine regulation must be do after working times learning Normally the trimmer goes in the center in this position should be possible to respect rul...

Page 18: ...ransmitters The new code takes the same channel as the one used to insert it Board settings Base Menu Push enter 1 for at least 1 second to enter base menu OL is on the display with up down it s possi...

Page 19: ...select EX or push up down together LT learn working time Attention before to start learning procedure the gate must be open to do automatic procedure otherwise must be closed to do the manual procedu...

Page 20: ...r1 Q1 open motor2 C2 close motor2 EX Exit Keep pushed enter to start the selected motor in dead man mode Board settings Advanced Menu Push enter button till on the display is shown TM With up down it...

Page 21: ...ing DC Motors delay closing TL Electric lock activation menu EX Exits from advanced menu Once selected working times to be changed use up down to modify it from 0 to 99 seconds Push enter to confirm T...

Page 22: ...tters without accessing base menu Refer to Automatic transmitters learning C5 Enable kickback stroke In this menu you can enabled the stroke at start to unlock electric lock and the final stroke to lo...

Page 23: ...22 Default settings Factory presets Herr it follows list default settings The same set after a D2 command of advanced menu Figure 20...

Page 24: ...r the sake of safety each gate is suggested to be equipped with infrared protector and regular inspection is required Before installation and operation of the gate opener please read all instructions...

Page 25: ...be mutually aligned 3 Remove the obstacle 4 Reduce the sensitivity of obstacle Remote control doesn t work 1 Battery level of the remote control is low 2 Remote control learning is not completed 1 Cha...

Page 26: ...fter the date of invoice 3 Without unauthorized dismantling any product broken or damage due to quality problem we ll offer the repair service for free or replace for free 4 The malfunction and damage...

Reviews: