Specification
Permissible ambient temperature
– During operation
0 to +40 °C
– During storage and transport
−20 to +70 °C
Setting range for glycol volume ra-
tio
0 to 70 %
Flow meter
06
15
25
35
60
Dimension a in mm
110
110
130
—
—
Pulse rate
l/imp.
1
10
25
25
25
Internal diameter
DN
15
15
20
25
32
Connection thread at the meter
R
¾
¾
1
1¼
1½
Connection thread at the fitting
R
½
½
¾
1
1¼
Max. operating pressure
bar
16
16
16
16
16
Max. operating temperature
°C
120
120
120
130
130
Sensor wells G½ x
mm
45
45
60
60
60
The following details refer to the water flow rate. If glycol mixtures are used, the different viscosities will result in deviations.
Nominal flow rate
m
3
/h
0.6
1.5
2.5
3.5
6.0
Peak flow rate
m
3
/h
1.2
3
5
7
12
Cut point ±3 %
l/h
48
120
200
280
480
Lowest flow rate (horizontal installation)
l/h
12
30
50
70
120
Lowest flow rate (vertical installation)
l/h
24
60
100
—
—
Pressure drop at approx. ⅔ of the nominal flow
rate
bar
0.1
0.1
0.1
0.1
0.1
Solar cell
Part no. 7408 877
34
31
70
The solar cell captures the intensity of the sun and communicates this
to the solar control unit. The bypass pump will be switched ON if the
insolation exceeds the set switching threshold.
With connecting cable, 2.3 m long.
On-site extension of the connecting lead:
2-core lead, length max. 35 m with a cross-section of 1.5 mm
2
(cop-
per).
Large display
Part no. 7438 325
To visualise the collector and cylinder temperatures as well as the
energy yield.
With power supply unit plug.
530
100
630
Specification
Power supply
9 V– plug power supply unit
230 V~, 50 to 60 Hz
Power consumption
max. 12 VA
BUS connection
V BUS
IP rating
IP 30
(in dry rooms)
Permissible ambient temperature
during operation, storage and
transport
0 to 40 °C
High limit safety cut-out
Part no. Z001 889
■ With a thermostatically controlled system.
■ With stainless steel sensor well R½ x 200 mm.
■ With setting scale and reset button in the casing.
■ Required if less than 40 litres cylinder capacity is available per m
2
absorber area. This reliably prevents temperatures above 95 °C in
the DHW cylinder.
Solar control units
(cont.)
54