Dimensions Vitocell 160-E
Cylinder capacity
l
750
950
Length (
7
)
a
mm
1004
1004
Width
b
mm
1059
1059
Height
c
mm
1895
2195
d
mm
1777
2083
e
mm
1547
1853
f
mm
967
1119
g
mm
676
752
h
mm
386
386
k
mm
155
155
l
mm
75
75
m
mm
991
1181
n
mm
370
370
Length (
7
) excl. thermal in-
sulation
o
mm
790
790
p
mm
140
140
Pressure drops
Heating water flow rate
in l/h
0.1
0.09
0.08
0.07
0.06
0.05
0.04
0.03
0.02
0.7
0.6
0.5
0.4
0.3
0.2
1000
2000
3000
4000
5000
Pressure drop in mbar
1
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
6
5
4
3
2
kPa
7
kPa
Pressure drop on the heating water side
2000
100
1
2
3
4
5
6
1.0
8
2.0
3.0
4.0
5.0
6.0
10.0
8.0
20.0
30.0
40.0
50.0
60.0
100.0
80.0
200
300
400 500 600
800 1000
2000
A
B
0.1
0.2
0.3
0.4
0.5
0.6
0.8
1
2
3
4
5
6
10
8
20
30
40
50
60
100
80
200
300
400
500
600
800
1000
kPa
Pressure drop in
Process medium flow rate in
mbar
l/h
Pressure drop on the solar side
A
Cylinder capacity 750 l
B
Cylinder capacity 950 l
DHW cylinders
(cont.)
VITOSOL
VIESMANN
81
5822 440 GB