Internal H2 extension
Fig. 53
The internal extension is integrated into the control unit
enclosure. The following alternative functions can be
connected to relay output
sK
. The function is assigned
via coding address "53" in the
"General"
group:
■
Central fault message (code "53:0")
■
DHW circulation pump (code "53:1") (only for
weather-compensated operation)
Connect DHW circulation pumps with standalone
functions directly to the 230 V
∼
supply.
An extractor fan can be switched off via connection
aBJ
when the burner starts.
lH
Power supply for accessories and Vitotrol 100
Function description
Internal extensions
(cont.)
5792 925 GB
Functions