28
Extension kit for one heating circuit
with mixer M2
Required coding
Address
One heating circuit with mixer
■ with DHW cylinder
00:4
■ without DHW cylinder
00:3
Function relay of the internal extension: Circulation pump for
cylinder heating
53:3
System version 3
One heating circuit without mixer A1 and one heating circuit with mixer M2,
with low loss header (with/without DHW heating)
1
3
6
5
M
qR
qT
8
7
9
qP
qQ
qW
qE
4
2
1
Vitodens 200-W
2
Outside temperature sensor
3
Boiler circuit pump
4
Circulation pump for cylinder heat-
ing
5
DHW cylinder
6
Cylinder temperature sensor
7
Heating circuit without mixer A1
8
Heating circuit pump A1
9
Heating circuit with mixer M2
qP
Temperature limiter for limiting the
maximum temperature of underfloor
heating systems
Flow temperature sensor M2
qW
Heating circuit pump M2
qE
Extension kit for one heating circuit
with mixer M2
qR
Low loss header
Commissioning, inspection, maintenance
Further details regarding the individual steps
(cont.)
5692 760 GB