28
Required equipment
Pos.
Designation
1
Heat pump
2
Vitotronic 200 heat pump control unit with connecting cables
3
Outside temperature sensor
4
Instantaneous heating water heater, 3, 6, or 9 kW (accessory)
5
Type AWCI-M-AC 301.A: 3-way diverter valve for "Central heating/DHW
heating"
Type AWO-M-AC 301.A: Circulation pump for cylinder heating
6
Secondary pump
7
Flow temperature sensor (integrated in the appliance for type AWCI-M-AC
301.A)
8
KM BUS distributor
qW
Safety equipment block with safety assembly
qE
Expansion vessel
DHW heating
eP
Vitocell 100-V DHW cylinder, type CVW, 390 litres
eQ
Cylinder temperature sensor, top
eU
DHW circulation pump ZP
DHW heating with a solar thermal system
eP
Vitocell 100-V DHW cylinder, type CVW, 390 litres
eQ
Cylinder temperature sensor, top
eW
Cylinder temperature sensor in the solar return
eU
DHW circulation pump ZP
eO
Solar heat exchanger set for installation on the Vitocell 100-V, type CVW
rQ
High limit safety cut-out STB 95 °C (if required)
rW
Solar-Divicon with solar circuit pump R1
rE
rR
Collector temperature sensor
rT
Solar collector
rU
Vitosolic 100, type SD1
Preparing for installation
System example 1, ID: 4605093_1006_01
(cont.)
5692 875 GB
Содержание Vitocal 300 AWO-M-AC 301.A
Страница 5: ...5 Certificates Declaration of conformity 148 Keyword index 149 Index Index cont 5692 875 GB...
Страница 47: ...47 Installation sequence Removing the transport brackets cont 5692 875 GB Installation...
Страница 49: ...49 3x 9x 3 3x 3x 2 3 4 1 Installation sequence Fitting the outer panels cont 5692 875 GB Installation...
Страница 52: ...52 3x 3x 3x 3x 9 8 Installation sequence Fitting the outer panels cont 5692 875 GB...
Страница 53: ...53 3x 10 3x 2x 11 Installation sequence Fitting the outer panels cont 5692 875 GB Installation...
Страница 57: ...57 Type AWCI M AC 301 A 1 Installation sequence Siting the heat pump cont 5692 875 GB Installation...
Страница 58: ...58 Type AWO M AC 301 A 2 3 4 5 4x 1 Installation sequence Siting the heat pump cont 5692 875 GB...
Страница 104: ...104 Fitting the front panel 1 2 2 Installation sequence Closing the heat pump cont 5692 875 GB...
Страница 127: ...127 022 029 032 034 033 031 033 025 031 Parts lists Parts list type AWCI M AC 301 A cont 5692 875 GB Service...
Страница 128: ...128 051 052 008 066 038 063 064 Parts lists Parts list type AWCI M AC 301 A cont 5692 875 GB...
Страница 134: ...134 022 029 032 033 031 033 025 031 Parts lists Parts list type AWO M AC 301 A cont 5692 875 GB...
Страница 135: ...135 051 052 008 065 038 063 064 Parts lists Parts list type AWO M AC 301 A cont 5692 875 GB Service...